Photodetection-induced relative timing jitter in synchronized time-lens source for coherent Raman scattering microscopy
Open Access
- 1 September 2017
- journal article
- research article
- Published by World Scientific Pub Co Pte Ltd in Journal of Innovative Optical Health Sciences
- Vol. 10 (05) , 1743003
Abstract
Synchronized time-lens source is a novel method to generate synchronized optical pulses to mode-locked lasers, and has found widespread applications in coherent Raman scattering microscopy. Relative timing jitter between the mode-locked laser and the synchronized time-lens source is a key parameter for evaluating the synchronization performance of such synchronized laser systems. However, the origins of the relative timing jitter in such systems are not fully determined, which in turn prevents the experimental efforts to optimize the synchronization performance. Here, we demonstrate, through theoretical modeling and numerical simulation, that the photodetection could be one physical origin of the relative timing jitter. Comparison with relative timing jitter due to the intrinsic timing jitter of the mode-locked laser is also demonstrated, revealing different qualitative and quantitative behaviors. Based on the nature of this photodetection-induced timing jitter, we further propose several strategies to reduce the relative timing jitter. Our theoretical results will provide guidelines for optimizing synchronization performance in experiments.Keywords
Funding Information
- National Natural Science Foundation of China (11404218)
- Science and Technology Innovation Commission of Shenzhen (KQJSCX20160226194151, JCYJ20160307150657874, KQTD20150710165601017)
- Project of Department of Education of Guangdong Province (2014KTSCX114)
- Natural Science Foundation of SZU (00002701)
This publication has 20 references indexed in Scilit:
- Nonresonant background suppression for coherent anti-Stokes Raman scattering microscopy using a multi-wavelength time-lens sourceOptics Express, 2016
- Contributed Review: A new synchronized source solution for coherent Raman scattering microscopyReview of Scientific Instruments, 2016
- Quantitative Vibrational Imaging by Hyperspectral Stimulated Raman Scattering Microscopy and Multivariate Curve Resolution AnalysisAnalytical Chemistry, 2012
- Perfectly registered multiphoton and reflectance confocal video rate imaging of in vivo human skinJournal of Biophotonics, 2012
- Fiber delivered two-color picosecond source through nonlinear spectral transformation for coherent Raman scattering imagingApplied Physics Letters, 2012
- Synchronized time-lens source for coherent Raman scattering microscopyOptics Express, 2010
- High-repetition-rate two-color pump–probe system directly pumped by a femtosecond ytterbium oscillatorOptics Letters, 2009
- Label-Free Biomedical Imaging with High Sensitivity by Stimulated Raman Scattering MicroscopyScience, 2008
- Three-Dimensional Vibrational Imaging by Coherent Anti-Stokes Raman ScatteringPhysical Review Letters, 1999
- Active pulse compression using an integrated electro-optic phase modulatorApplied Physics Letters, 1988