MRI Safety Practice Observations in MRI Facilities Within the Kingdom of Jordan, Compared to the 2020 Manual on MR Safety of the American College of Radiology
Open Access
- 1 May 2022
- journal article
- research article
- Published by Taylor & Francis in Medical Devices: Evidence and Research
- Vol. ume 15, 131-142
Abstract
Purpose: The absence of ionizing radiation in MRI applications does not guarantee absolute safety. Implementing of safety guidelines can ensure high-quality practice in the clinical MRI with the minimum risk. For this purpose, this cross-section quantitative study conducted in Jordan Kingdom aimed to assess current MRI safety guidelines in comparison with those of 2020 Manual on MR Safety of the American College of Radiology (ACR). Patients and Methods: A site observation study of 38 MRI units was undertaken in June 2021. A well-structured MRI safety questionnaire was the primary data collection method. Data were subjected to a descriptive statistics content analysis by the SPSS version 20. The results were analyzed to yield comprehensive discussions. Results: A total of 38 MRI facilities in participated in this study with the responding rate of 44.7%. Patient screening areas and changing rooms were available in about 29% (11/38) of the MRI facilities. Most facilities (55%, 21/38) conducted verbal screening only whereas 21% implemented both written and verbal screening for their patients and companions in zone II, which was present in a percentage of 29% in the approached facilities. Meanwhile, only 13 (43.2%) of 38 facilities used handheld magnets for physical screening, 25 (65.8%) of MRI units did not use any kind of ferromagnetic metal detection systems. Three (7.9%) participating centers had MR-safe wheelchairs, ventilators, anesthesia machines, and stretchers. Most MRI facilities participating in this study (71%) had emergency preparedness plans for alternative power outages. Despite a relatively low number of participating centers having an emergency exit or code (26.3% and 10.5%, respectively), none of them performed practice drills for such scenarios. Conclusion: Investing in new MR-safe equipment requires introducing ferromagnetic detecting systems. More research is needed to establish the degree of MRI professional’s safety-related education.Keywords
This publication has 40 references indexed in Scilit:
- Prevalence of Unanticipated Events Associated With MRI Examinations: A Benchmark for MRI Quality, Safety, and Patient ExperienceJournal of the American College of Radiology, 2017
- A Practical Guide to MR Imaging Safety: What Radiologists Need to KnowRadioGraphics, 2015
- Lessons Learned from MRI Safety EventsCurrent Radiology Reports, 2015
- Implementation of a ferromagnetic detection system in a clinical MRI settingRadiography, 2015
- An open source automatic quality assurance (OSAQA) tool for the ACR MRI phantomAustralasian Physics & Engineering Sciences in Medicine, 2014
- Detection of Implants and Other Objects Using a Ferromagnetic Detection System: Implications for Patient Screening Before MRIAmerican Journal of Roentgenology, 2013
- Assessment of Safety Standards of Magnetic Resonance Imaging at the Korle Bu Teaching Hospital (KBTH) in Accra, Ghana2013
- What are the basic concepts of temporal, contrast, and spatial resolution in cardiac CT?Journal of Cardiovascular Computed Tomography, 2009
- Biological Effects and Safety in Magnetic Resonance Imaging: A ReviewInternational Journal of Environmental Research and Public Health, 2009
- ACR Guidance Document for Safe MR Practices: 2007American Journal of Roentgenology, 2007