Accuracy and Systematic Biases of Heart Rate Measurements by Consumer-Grade Fitness Trackers in Postoperative Patients: Prospective Clinical Trial
Authors:
- Philipp HelmerPHPhilipp Helmer
- Sebastian HottenrottSHSebastian Hottenrott
- Philipp RodemersPRPhilipp Rodemers
- Robert LeppichRLRobert Leppich
- Maja HelwichMHMaja Helwich
- Rüdiger PryssRüdiger Pryss
- Peter KrankePKPeter Kranke
- Patrick MeybohmPMPatrick Meybohm
- Bernd E WinklerBWBernd E Winkler
- Michael SammethMSMichael Sammeth
Open Access
- 30 December 2022
- journal article
- research article
- Published by JMIR Publications Inc. in Journal of Medical Internet Research
- Vol. 24 (12) , e42359
Abstract
Background: Over the recent years, technological advances of wrist-worn fitness trackers heralded a new era in the continuous monitoring of vital signs. So far, these devices have primarily been used for sports. Objective: However, for using these technologies in health care, further validations of the measurement accuracy in hospitalized patients are essential but lacking to date. Methods: We conducted a prospective validation study with 201 patients after moderate to major surgery in a controlled setting to benchmark the accuracy of heart rate measurements in 4 consumer-grade fitness trackers (Apple Watch 7, Garmin Fenix 6 Pro, Withings ScanWatch, and Fitbit Sense) against the clinical gold standard (electrocardiography). Results: All devices exhibited high correlation (r≥0.95; P<.001) and concordance (rc≥0.94) coefficients, with a relative error as low as mean absolute percentage error <5% based on 1630 valid measurements. We identified confounders significantly biasing the measurement accuracy, although not at clinically relevant levels (mean absolute error<5 beats per minute). Conclusions: Consumer-grade fitness trackers appear promising in hospitalized patients for monitoring heart rate. Trial Registration: ClinicalTrials.gov NCT05418881; https://www.clinicaltrials.gov/ct2/show/NCT05418881Keywords
This publication has 35 references indexed in Scilit:
- Pilot Study Assessing the Influence of Skin Type on the Heart Rate Measurements Obtained by Photoplethysmography with the Apple WatchJournal of Medical Systems, 2019
- Version Reporting and Assessment Approaches for New and Updated Activity and Heart Rate MonitorsSensors, 2019
- Accuracy of Apple Watch Measurements for Heart Rate and Energy Expenditure in Patients With Cardiovascular Disease: Cross-Sectional StudyJMIR mHealth and uHealth, 2019
- Accuracy of Consumer Wearable Heart Rate Measurement During an Ecologically Valid 24-Hour Period: Intraindividual Validation StudyJMIR mHealth and uHealth, 2019
- Acceptability and feasibility of wearing activity monitors in community‐dwelling older adults with dementiaInternational Journal of Geriatric Psychiatry, 2019
- The impact of continuous versus intermittent vital signs monitoring in hospitals: A systematic review and narrative synthesisInternational Journal of Nursing Studies, 2018
- Variable Accuracy of Wearable Heart Rate Monitors during Aerobic ExerciseMedicine & Science in Sports & Exercise, 2017
- Accuracy of a Wrist-Worn Wearable Device for Monitoring Heart Rates in Hospital Inpatients: A Prospective Observational StudyJournal of Medical Internet Research, 2016
- Systematic review of the validity and reliability of consumer-wearable activity trackersInternational Journal of Behavioral Nutrition and Physical Activity, 2015
- Measuring agreement in method comparison studiesStatistical Methods in Medical Research, 1999