A Switched-Capacitor Front-End for Velocity-Selective ENG Recording
Authors:
- 5 February 2013
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 7 (4) , 480-488
Abstract
Multi-electrode cuffs (MECs) have been proposed as a means for extracting additional information about the velocity and direction of nerve signals from multi-electrode recordings. This paper discusses certain aspects of the implementation of a system for velocity selective recording (VSR) where multiple neural signals are matched and summed to identify excited axon populations in terms of velocity. The approach outlined in the paper involves the replacement of the digital signal processing stages of a standard delay-matched VSR system with analogue switched-capacitor (SC) delay lines which promises significant savings in both size and power consumption. The system specifications are derived and two circuits, each composed of low-noise preamplifiers connecting to a 2nd rank SC gain stage, are evaluated. One of the systems provides a single-ended SC stage whereas the other system is fully differential. Both approaches are shown to provide the low-noise, low-power operation, practically identical channel gains and sample delay range required for VSR. Measured results obtained from chips fabricated in 0.8 μm CMOS technology are reported.Keywords
This publication has 24 references indexed in Scilit:
- Signal processing for velocity selective recording systems using analogue delay lines2012
- A Multichannel Integrated Circuit for Electrical Recording of Neural Activity, With Independent Channel ProgrammabilityIEEE Transactions on Biomedical Circuits and Systems, 2012
- A low-noise front-end for multiplexed ENG recording using CMOS technologyAnalog Integrated Circuits and Signal Processing, 2011
- A 128-Channel 6 mW Wireless Neural Recording IC With Spike Feature Extraction and UWB TransmitterIEEE Transactions on Neural Systems and Rehabilitation Engineering, 2009
- Brain–Silicon Interface for High-Resolution in vitro Neural RecordingIEEE Transactions on Biomedical Circuits and Systems, 2007
- Analog frontend for multichannel neuronal recording system with spike and LFP separationJournal of Neuroscience Methods, 2006
- A low noise multichannel integrated circuit for recording neuronal signals using microelectrode arraysBiosensors and Bioelectronics, 2004
- Two multichannel integrated circuits for neural recording and signal processingIEEE Transactions on Biomedical Engineering, 2003
- Single-unit neural recording with active microelectrode arraysIEEE Transactions on Biomedical Engineering, 2001
- An implantable CMOS circuit interface for multiplexed microelectrode recording arraysIEEE Journal of Solid-State Circuits, 1992