Structure design and mechanical performance analysis of three kinds of bioresorbable poly-lactic acid (PLA) stents
Authors:
- 26 March 2022
- journal article
- research article
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 26 (1) , 25-37
Abstract
Vascular stent implantation has become an important choice for the treatment of severe cardiovascular and cerebrovascular blockage. Rational design is vital to ensure the mechanical properties of the vascular stents, which are important both to the implantation and service as for clinical treatment of coronary heart disease. Therefore we proposed a wholly new non-uniform honeycomb stent E and compared with an inverted honeycomb-like shaped stent F and a honeycomb-like shaped stent G. To evaluate their properties, a finite element method (FEM) was used to simulate the implantation process (crimp, crimp recoil, expand, and expand recoil) of these three different kinds of stents. Results showed that the stent E exhibits better mechanical behaviour than the other two stents F and G as far as radial strength and axial shortening performances and that the distribution of equivalent stress among the stent E is more uniform than that among the other two stents F and G. After that, a three-point bending method was used to study the bending flexibility of these three vascular stents. Stent E shows high bending stiffness compared with stents F and G due to the existence of additional support bridges in its structure. This study can be helpful to the rational design of optimizable PLA stents for its practical clinical performance and therefore possibly improve the prognosis of patients.Keywords
This publication has 25 references indexed in Scilit:
- Design optimization of stent and its dilatation balloon using kriging surrogate modelBioMedical Engineering OnLine, 2017
- Computational and experimental investigation into mechanical performances of Poly-L-Lactide Acid (PLLA) coronary stentsJournal of the Mechanical Behavior of Biomedical Materials, 2017
- Finite element analyses for optimization design of biodegradable magnesium alloy stentMaterials Science and Engineering: C, 2014
- Analyses and design of expansion mechanisms of balloon expandable vascular stentsJournal of Biomechanics, 2014
- Numerical investigations of the structural behavior of a balloon expandable stent design using finite element methodComputational Materials Science, 2013
- A comparison of the mechanical performance characteristics of seven drug‐eluting stent systemsCatheterization and Cardiovascular Interventions, 2009
- Mechanical Properties of Laser Cut Poly(L-Lactide) Micro-Specimens: Implications for Stent Design, Manufacture, and SterilizationJournal of Biomechanical Engineering, 2005
- Antithrombotic Potential of Polymer-Coated Stents Eluting Platelet Glycoprotein IIb/IIIa Receptor AntibodyCirculation, 1996
- A Randomized Comparison of Coronary-Stent Placement and Balloon Angioplasty in the Treatment of Coronary Artery DiseaseNew England Journal of Medicine, 1994
- TREATMENT OF RENOVASCULAR HYPERTENSION WITH PERCUTANEOUS TRANSLUMINAL DILATATION OF A RENAL-ARTERY STENOSISThe Lancet, 1978