High resolution transbulbar sonography in children with suspicion of increased intracranial pressure
- 13 January 2016
- journal article
- Published by Springer Nature in Child's Nervous System
- Vol. 32 (4) , 655-660
Abstract
To evaluate the accuracy of high resolution transbulbar sonography for the estimation of intracranial pressure (ICP) in children. In children and adolescents with acute neurologic symptoms of various origin, transbulbar sonography was performed. Besides measurement of the optic nerve sheath diameter (ONSD), the ultrastructure of the subarachnoid space of the optic nerve sheath was evaluated. The results of transbulbar sonography were correlated with clinical data based on cross-sectional imaging, ICP measurement, and ophthalmologic examination. Eighty-one patients (age 3–17.8 years, mean 11.7 years) were included. In 25 children, cross-sectional imaging and ICP measurement revealed increased intracranial pressure. The mean ONSD was 6.85 ± 0.81 mm. Twenty patients (20/25, 80 %) had a microcystic appearance of the subarachnoid space of the optic nerve. In 56 children without evidence of increased intracranial pressure, the mean ONSD was 5.77 ± 0.48 mm. Forty-nine patients (49/56, 87.5 %) had a normal homogenous appearance of the subarachnoid space. The ONSD in children with increased intracranial pressure was significantly higher than in patients without (p < 0.001). High resolution transbulbar sonography of the optic nerve is a useful technique for the rapid and non-invasive estimation of intracranial pressure in children. Besides measurement of the optic nerve sheath diameter, evaluation of the ultrastructure of the subarachnoid space of the optic nerve is a helpful parameter.Keywords
This publication has 28 references indexed in Scilit:
- High Resolution Ultrasound and Magnetic Resonance Imaging of the Optic Nerve and the Optic Nerve Sheath: Anatomic Correlation and Clinical ImportanceUltraschall in der Medizin - European Journal of Ultrasound, 2010
- Reference Range for Cerebrospinal Fluid Opening Pressure in ChildrenNew England Journal of Medicine, 2010
- MR Imaging of the Optic Nerve Sheath in Patients with Craniospinal HypotensionAmerican Journal of Neuroradiology, 2010
- Bedside Sonographic Measurement of Optic Nerve Sheath Diameter as a Predictor of Increased Intracranial Pressure in ChildrenAnnals of Emergency Medicine, 2009
- Use of T2-weighted magnetic resonance imaging of the optic nerve sheath to detect raised intracranial pressureCritical Care, 2008
- Pseudotumor cerebri: Quantitative Normalwerte anatomischer Kennstrukturen im kraniellen MRTRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2008
- Correlation of Optic Nerve Sheath Diameter with Direct Measurement of Intracranial PressureAcademic Emergency Medicine, 2008
- Morphometry of the Retrobulbar Human Optic Nerve: Comparison between Conventional Sonography and Ultrafast Magnetic Resonance SequencesInvestigative Ophthalmology & Visual Science, 2007
- Fast and Quantitative High-Resolution Magnetic Resonance Imaging of the Optic Nerve at 3.0 TeslaInvestigative Radiology, 2006
- Fundamentals of transorbital sonographic evaluation of optic nerve sheath expansion under intracranial hypertensionPediatric Radiology, 1996