Bilateral Weighted Relative Total Variation for Low-Dose CT Reconstruction
Authors:
- 28 November 2022
- journal article
- research article
- Published by Springer Nature in Journal of Digital Imaging
- Vol. 36 (2) , 458-467
Abstract
Low-dose computed tomography (LDCT) has been widely used for various clinic applications to reduce the X-ray dose absorbed by patients. However, LDCT is usually degraded by severe noise over the image space. The image quality of LDCT has attracted aroused attentions of scholars. In this study, we propose the bilateral weighted relative total variation (BRTV) used for image restoration to simultaneously maintain edges and further reduce noise, then propose the BRTV-regularized projections onto convex sets (POCS-BRTV) model for LDCT reconstruction. Referring to the spacial closeness and the similarity of gray value between two pixels in a local rectangle, POCS-BRTV can adaptively extract sharp edges and minor details during the iterative reconstruction process. Evaluation indexes and visual effects are used to measure the performances among different algorithms. Experimental results indicate that the proposed POCS-BRTV model can achieve superior image quality than the compared algorithms in terms of the structure and texture preservation.Keywords
Funding Information
- National Natural Science Foundation of China (61771003)
- Graduate research and innovation foundation of Chongqing, China (CYB21044)
- General Project of Chongqing Natural Science Foundation (cstc2021jcyj-msxmX0679)
- Science and Technology Research Program of Chongqing Education Commission of China (KJQN202000808)
This publication has 33 references indexed in Scilit:
- Few-view image reconstruction with dual dictionariesPhysics in Medicine & Biology, 2011
- Low-dose CT reconstruction via edge-preserving total variation regularizationPhysics in Medicine & Biology, 2011
- Cone-beam CT with a flat-panel detector: From image science to image-guided surgeryNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2011
- CT-Guided Percutaneous Biopsy of a Mass Lesion in the Upper Presacral Space: A Sacral Transneuroforaminal ApproachCardioVascular and Interventional Radiology, 2011
- A constrained, total-variation minimization algorithm for low-intensity x-ray CTMedical Physics, 2011
- Computed Tomography — An Increasing Source of Radiation ExposureNew England Journal of Medicine, 2007
- Principles of CT and CT TechnologyJournal of Nuclear Medicine Technology, 2007
- Nonlocal Image and Movie DenoisingInternational Journal of Computer Vision, 2007
- Principles of Computerized Tomographic ImagingMedical Physics, 2002
- Image restoration by Wiener deconvolution in limited-view computed tomographyApplied Optics, 1985