Comparison of Three Different Tonometers in Eyes with Angle Closure
Authors:
- 1 February 2019
- journal article
- research article
- Published by Wiley in Optometry and Vision Science
- Vol. 96 (2) , 124-129
Abstract
Supplemental digital content is available in the text. SIGNIFICANCE: Precise measurement of intraocular pressure (IOP) is essential when diagnosing and managing glaucoma. We compared the IOP readings of three different tonometers and analyzed agreement among tonometers in eyes with high IOPs. PURPOSE: The purpose of this study was to compare the IOP readings obtained using a Goldmann applanation tonometer (GAT), a rebound tonometer (RT), and a Tono‐Pen (TP) in angle‐closure eyes with elevated IOP before and after medical IOP‐lowering therapy. METHODS: Twenty‐five eyes of 25 patients with angle closure and IOPs of greater than 30 mmHg were enrolled. Intraocular pressure was measured using RT (iCare Pro), TP (Tono‐Pen XL), and GAT before and after medical treatment. The mean IOP readings of the tonometers were compared before and after treatment. The agreement among the tonometers was assessed via Bland‐Altman analysis. RESULTS: The measurements from 22 eyes of 22 patients were suitable for statistical analyses. Before medical treatment, the mean TP‐IOP was significantly lower than the mean GAT‐IOP (44.0 ± 10.3 vs. 50.4 ± 8.9 mmHg, respectively; P <. 001), but no significant difference was evident between the RT‐IOP and the GAT‐IOP (50.8 ± 10.9 vs. 50.4 ± 8.9 mmHg, respectively; P =. 79). After IOP‐lowering treatment, the mean GAT‐IOP (14.9 ± 4.7 mmHg) did not differ from either the mean RT‐IOP (15.6 ± 4.4 mmHg) or the mean TP‐IOP (15.4 ± 5.0 mmHg; P =. 05 and P =. 18, respectively). The random measurement error among tonometers was greater for high IOP readings. CONCLUSIONS: Compared with RT or GAT, TP underestimated IOP in angle‐closure eyes with a GAT‐IOP of greater than 30 mmHg. Intraocular pressure reading agreement among the three tonometers was lower in eyes with high IOP.Keywords
This publication has 42 references indexed in Scilit:
- Evaluation of the ICare Rebound Tonometer as a Home Intraocular Pressure Monitoring DeviceJournal of Glaucoma, 2011
- Tonometry in the general practice setting (I)Acta Ophthalmologica, 2009
- The effect of repeated applanation on subsequent IOP measurementsClinical and Experimental Optometry, 2008
- Relationship of Progression of Visual Field Damage to Postural Changes in Intraocular Pressure in Patients with Normal-Tension GlaucomaOphthalmology, 2006
- Telemedicine‐friendly, portable tonometers: an evaluation for intraocular pressure screeningClinical & Experimental Ophthalmology, 2006
- Comparison of the ICare® rebound tonometer with the Goldmann tonometer in a normal populationOphthalmic and Physiological Optics, 2005
- The advanced glaucoma intervention study (AGIS): 7. the relationship between control of intraocular pressure and visual field deteriorationAmerican Journal of Ophthalmology, 2000
- Accuracy of Goldmann tonometry in clinical practiceActa Ophthalmologica, 1993
- Tono-Pen, a new tonometerInternational Ophthalmology, 1989
- ON REPEATED TONOMETRYActa Ophthalmologica, 1971