Comparative evaluation of different anchoring techniques for synthetic cruciate ligaments
Author:
- 1 June 1994
- journal article
- research article
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 2 (2) , 107-117
Abstract
Under certain well‐defined indications alloplastic material may be used in cruciate ligament surgery. The stability and survival of such a synthetic ligament is to a great extent dependent on the anchorage with which it is fastened to the bone. Most fixation methods have proved to be too weak or have revealed other essential drawbacks, resulting in clinical and experimental failure. A new ligament fixation device (LFD) was developed and tested biomechanically and in animal experiments. In the biomechanic investigation the new LFD was compared to single staples, double staples in the belt‐buckle technique, and ligament guidance through additional bone tunnels (Z‐technique). The tests were carried out on human cadaver knees, plastic bones, and dog stifle joints. The evaluated parameters were linear and maximum load, stiffness, and elongation. In addition, hysteresis tests were performed to assay the long‐term resistance of the fixation. The tests showed a significant superiority of the LFD in all measured variables compared to the other anchorages. The pull‐out strength, at 1866±43 N (cadaver knee), was about four times that for the single staple, and about twice as high as that for the double staple and Ztechnique. The animal experiments were performed on German shepherd cross‐breed dogs. In six animals the anterior cruciate ligaments were excised bilaterally and replaced by a 6‐mm Trevira ligament, on one side anchored with staples in the Z‐technique, on the other with the LFD. Postoperatively the dogs were allowed to move freely: no additional protection was employed. After 6 months the animals were sacrificed and the knees examined macroscopically. radiologically, microscopically, and by biomechanical testing. After half a year of implantation, the pull‐out strength of the alloplastic ligament was 662±62 N for the LFD and 531±67 N for the staples. Three ligaments in the staple group and one in the LFD group had ruptured completely, and two ligaments partially, one in each group. The average anterior drawer in the LFD group was 2.8 mm, in the staple group 4.0 mm. In all cases the alloplastic ligament was separated from the bone by a fibrous interface. None of the fixation devices showed signs of loosening. There was no foreign body reaction around the anchorages. Major cartilage degeneration was observed in two stifle joints of each group, mainly associated with instability.Keywords
This publication has 37 references indexed in Scilit:
- Dacron ligament reconstruction for chronic anterior cruciate ligament insufficiencyThe American Journal of Sports Medicine, 1993
- Reconstruction of old anterior cruciate ligament tears with a Dacron prosthesisThe American Journal of Sports Medicine, 1993
- Augmented repair and early mobilization of acute anterior cruciate ligament injuriesThe American Journal of Sports Medicine, 1992
- Reconstruction of chronic insufficient anterior cruciate ligament in the knee using a synthetic Dacron prosthesisThe American Journal of Sports Medicine, 1992
- Akute ACL-Rupturen, Polypropylenband-Augmentation in neuer Technik (Meißeltechnik) mit ErgebnissenZeitschrift für Orthopädie und ihre Grenzgebiete, 1991
- Staple migration simulating lateral meniscus injuryThe American Journal of Sports Medicine, 1990
- Late breakage of orthopaedic staple causing peroneal nerve palsyThe American Journal of Sports Medicine, 1990
- A multicenter study on the results of anterior cruciate ligament reconstruction using a Dacron ligament prosthesis in "salvage" casesThe American Journal of Sports Medicine, 1989
- Early experience with the GORE-TEX polytetrafluoroethylene anterior cruciate ligament prosthesisThe American Journal of Sports Medicine, 1989
- Vollautomatische Herstellung von Knochenschliffen bei exakter DickeneinstellungCells Tissues Organs, 1979