A randomized comparison of the Ambu AuraGain versus the LMA supreme in patients undergoing gynaecologic laparoscopic surgery
- 26 November 2016
- journal article
- research article
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 31 (6) , 1255-1262
Abstract
Second generation supraglottic airway devices providing high seal airway pressures are suitable for patients undergoing gynecologic laparoscopy. We compared the seal pressure achieved by the new Ambu AuraGain™ versus LMA Supreme™ following pneumoperitoneum in the Trendelenburg position. Sixty female patients were randomly allocated to ventilation with either the AuraGain or the Supreme. A target-controlled system was used to administer total intravenous anesthesia. Intracuff pressure was maintained below 60 cm H2O. The following parameters were registered: Time, number of attempts and manoeuvres required for insertion; seal pressure and peak inspiratory pressure at four time points; ease of gastric tube insertion, flexible scope view, complications and postoperative morbidity. Both devices were quick and easily inserted, although the Supreme required less rotation manoeuvres (16 in AuraGain vs. 6 in LMA Supreme; p = 0.01). The AuraGain achieved higher seal pressures (34 ± 5 in AuraGain vs. 29 ± 5 in LMA Supreme; p = 0.0002). Following pneumoperitoneum in head-down position, peak airway pressure increased 9 ± 3 cm H2O in both groups, exceeding seal pressure in 3 patients in the Supreme group (p = 0.06). The vocal cords were seen through all AuraGain and 90% of the Supreme devices; epiglottis was often visible inside the tube (68%). No differences were found in the incidence of traces of blood on the mask or postoperative symptoms. Both devices allowed effective ventilation in patients undergoing gynaecologic laparoscopic surgery with a low rate of complications. The Ambu AuraGain provided higher seal pressures and a clear view of glottic inlet in all patients offering the possibility to guide direct tracheal intubation if required.Keywords
This publication has 17 references indexed in Scilit:
- Brief review: The LMA Supreme™ supraglottic airwayCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 2012
- Pressure-controlled inverse ratio ventilation using laryngeal mask airway in gynecological laparoscopyJournal of Anaesthesiology Clinical Pharmacology, 2012
- Comparison of the Proseal LMA and intersurgical I-gel during gynecological laparoscopyKorean Journal of Anesthesiology, 2012
- Comparison of volume-controlled and pressure-controlled ventilation using a laryngeal mask airway during gynecological laparoscopyKorean Journal of Anesthesiology, 2011
- Comparison of the LMA Supreme vs the i‐gel™ in paralysed patients undergoing gynaecological laparoscopic surgery with controlled ventilation*Anaesthesia, 2010
- Use of Manometry for Laryngeal Mask Airway Reduces Postoperative Pharyngolaryngeal Adverse EventsAnesthesiology, 2010
- Sparing the larynx during gynecological laparoscopy: a randomized trial comparing the LMA Supreme™ and the ETTActa Anaesthesiologica Scandinavica, 2010
- Prospective Clinical and Fiberoptic Evaluation of the Supreme Laryngeal Mask Airway ™Anesthesiology, 2009
- LMA-Classic™ and LMA-ProSeal™ are effective alternatives to endotracheal intubation for gynecologic laparoscopyCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 2003
- Comparison of four methods for assessing airway sealing pressure with the laryngeal mask airway in adult patientsBritish Journal of Anaesthesia, 1999