Material wear of polymeric tracheostomy tubes: A six‐month study
- 9 February 2009
- journal article
- research article
- Published by Wiley in The Laryngoscope
- Vol. 119 (4) , 657-664
Abstract
Objectives: The objectives were to study long‐term material wear of tracheostomy tubes made of silicone (Si), polyvinyl chloride (PVC), and polyurethane (PU) after 3 and 6 months of clinical use.Study Design: The study has a prospective and comparative design.Methods: Nineteen patients with long‐term tracheostomy, attending the National Respiratory Center in Sweden, were included, n = 6 with Si tubes, n = 8 with PVC tubes, and n = 5 with PU tubes. The tubes were exposed to the local environment in the trachea for 3 and 6 months and analyzed by scanning electron microscopy, attenuated total reflectance Fourier transform infrared spectroscopy, and differential scanning calorimetry.Results: All tubes revealed severe surface changes. No significant differences were established after 3 or 6 months of exposure between the various materials. The changes had progressed significantly after this period, compared to previously reported changes after 30 days of exposure. The results from all analyzing techniques correlated well.Conclusions: All tubes, exposed in the trachea for 3–6 months, revealed major degradation and changes in the surface of the material. Polymeric tracheostomy tubes should be changed before the end of 3 months of clinical use. Laryngoscope, 2009Keywords
This publication has 25 references indexed in Scilit:
- Tracheostomy inner cannula care: A randomized crossover study of two decontamination proceduresAmerican Journal of Infection Control, 2007
- Bacterial biofilms within the clinical setting: what healthcare professionals should knowJournal of Hospital Infection, 2006
- Phthalate exposure and male infertilityToxicology, 2006
- A retrospective survey of outpatients with long‐term tracheostomyActa Anaesthesiologica Scandinavica, 2006
- Di(2‐ethylhexyl)phthalate (DEHP): human metabolism and internal exposure – an update and latest results1International Journal of Andrology, 2006
- Nanoscale Hydrophobic Recovery: A Chemical Force Microscopy Study of UV/Ozone-Treated Cross-Linked Poly(dimethylsiloxane)Langmuir, 2003
- Regular Tracheostomy Tube Changes to Prevent Formation of Granulation TissueThe Laryngoscope, 2003
- Structural and mechanistic aspects of the thermal degradation of poly(vinyl chloride)Progress in Polymer Science, 2002
- Relevance of biofilms for the biodeterioration of surfaces of polymeric materials*Polymer Degradation and Stability, 1998
- Oxidants, antioxidants, and respiratory tract lining fluids.Environmental Health Perspectives, 1994