Geometric analysis of selected press fit prosthetic systems for proximal humeral replacement
Authors:
- 1 March 2002
- journal article
- research article
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 20 (2) , 192-197
Abstract
The ability of a prosthetic system to replicate a wide range of normal anatomy appears dependent in part to its capacity to produce variable prosthetic geometries. Several modern designs have recently been developed in order to provide multiple prosthetic options. The purpose of this study was to compare the geometry of select press fit prosthetic systems in terms of their ability to match normal three‐dimensional geometry of the proximal humerus. The anatomy of 60 humeral specimens from 30 cadavers known from CT data and computer‐aided design (CAD) analysis was compared to a 1996 database of four conventional shoulder prosthetic systems (fixed inclination angle, one medial‐lateral offset position per head) and one so‐called anatomic system (variable inclination angles, multiple head offset positions). The prosthetic system with greatest geometric options allowed for a significantly better replication of the anatomy. Average displacement of the center of rotation was 2.1 mm compared to 9.7 mm for the other systems combined. Reduction in surface arc was 12° compared to 32°. The most problematic feature of conventional prosthetic systems in terms of replicating normal humeral anatomy is the gap created by the prosthetic collar and Morse taper. © 2002 Orthopaedic Research Society. Published by Elsevier Science Ltd. All rights reserved.Keywords
This publication has 10 references indexed in Scilit:
- Geometric Analysis of Commonly Used Prosthetic Systems for Proximal Humeral Replacement*Journal of Bone and Joint Surgery, 1999
- THE THREE-DIMENSIONAL GEOMETRY OF THE PROXIMAL HUMERUSThe Journal of Bone and Joint Surgery. British volume, 1997
- Anthropometric study of normal glenohumeral relationshipsJournal of Shoulder and Elbow Surgery, 1997
- Coronal plane geometry of the proximal humerus relevant to prosthetic arthroplastyJournal of Shoulder and Elbow Surgery, 1996
- Retroversion of the proximal humerus in relationship to prosthetic replacement arthroplastyJournal of Shoulder and Elbow Surgery, 1995
- Limits imposed on glenohumeral motion by joint geometryJournal of Shoulder and Elbow Surgery, 1995
- Total shoulder arthroplasty: Some considerations related to glenoid surface contactJournal of Shoulder and Elbow Surgery, 1994
- Humeral head prosthetic arthroplasty: Surgically relevant geometric considerationsJournal of Shoulder and Elbow Surgery, 1993
- Articular Geometry of the Glenohumeral JointClinical Orthopaedics and Related Research, 1992
- The geometry of the humeral head and the design of prosthesesThe Journal of Bone and Joint Surgery. British volume, 1991