Diffuse Reflection Spectroscopy: An Alternative to Autofluorescence Spectroscopy in Tongue Cancer Detection
Authors:
- Rupananda Jayachandra MalliaRMRupananda Jayachandra Mallia
- Subhash NarayananSNSubhash Narayanan
- Jayaprakash MadhavanJMJayaprakash Madhavan
- Paul SebastianPSPaul Sebastian
- Rejnish KumarRKRejnish Kumar
- Anitha MathewsAMAnitha Mathews
- Gigi ThomasGTGigi Thomas
- Jayakrishnan RadhakrishnanJRJayakrishnan Radhakrishnan
- 1 April 2010
- journal article
- research article
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 64 (4) , 409-418
Abstract
Laser-induced autofluorescence (LIAF) and diffuse reflection spectroscopy (DRS) are two emerging noninvasive optical tools that have shown immense potential to detect oral cavity pre-cancer. In a recent study, we have used spectral ratio reference standards (SRRS) of LIAF intensity ratios F500/F635, F500/F685, and F500/F705 for grading of tissues belonging to sites other than dorsal side of tongue (DST), lateral side of tongue (LST), and vermillion border of lip (VBL) that exhibited similar spectral shape for normal and abnormal tissues. This led to dismal diagnostic accuracies, and for the three LIAF-SRRS, normal tissue values were often misclassified as squamous cell carcinoma (SCC), which means that the true negatives were being wrongly identified as true positives. This study examines the applicability of the site-specific diffuse reflection spectral intensity ratio (R545/R575) of the oxygenated hemoglobin bands to classify different DST lesions and compares the results obtained with those obtained using LIAF-SRRS. DRS-SRRS of R545/R575 differentiated benign hyperplastic DST tissues from normal tissue with a sensitivity of 86% and specificity of 80%, which were indistinguishable using LIAF-SRRS. Further, in distinguishing hyperplastic tissues from premalignant dysplastic lesions, DRS-SRRS gave a sensitivity of 90% and a specificity of 86%, as compared to sensitivity of 89% and specificity of 72% shown by the three LIAF-SRRS together. The diagnostic accuracy and statistical adequacy of the two techniques were assessed by receiver operating characteristic curve (ROC-Curve) analysis. Three LIAF ratios gave a low overall ROC area under curve (ROC-AUCs) of 0.521, whereas the DR ratio (R545/R575) has shown an improved accuracy of 0.970 in differentiating different tissue types. While distinguishing hyperplastic from dysplastic tissues, the DR ratio gave a higher discrimination accuracy of 0.9. Based on these findings, it can be concluded that the DRS-SRRS technique by virtue of its low cost and higher diagnostic accuracies could be a viable alternate to LIAF-SRRS for in vivo screening of tongue pre-cancers and grading of different tissue types.Keywords
This publication has 36 references indexed in Scilit:
- Oxygenated hemoglobin diffuse reflectance ratio for in vivo detection of oral pre-cancerJournal of Biomedical Optics, 2008
- Diagnosis of breast cancer using diffuse reflectance spectroscopy: Comparison of a Monte Carlo versus partial least squares analysis based feature extraction techniqueLasers in Surgery and Medicine, 2006
- Elastic scattering spectroscopy for the diagnosis of colonic lesions: initial results of a novel optical biopsy techniqueGastrointestinal Endoscopy, 2006
- Spectroscopic detection and evaluation of morphologic and biochemical changes in early human oral carcinomaCancer, 2003
- Preliminary study of detecting neoplastic growths in vivo with real time calibrated autofluorescence imagingOptics Express, 2003
- Multivariate analysis of laryngeal fluorescence spectra recorded in vivoLasers in Surgery and Medicine, 2001
- QUANTITATIVE OPTICAL SPECTROSCOPY FOR TISSUE DIAGNOSISAnnual Review of Physical Chemistry, 1996
- Spectroscopic diagnosis of bladder cancer with elastic light scatteringLasers in Surgery and Medicine, 1995
- Ultraviolet laser‐induced fluorescence of colonic tissue: Basic biology and diagnostic potentialLasers in Surgery and Medicine, 1992
- Basic principles of ROC analysisSeminars in Nuclear Medicine, 1978