Gravimetric flow standard in the vacuum and hermetic modes
- 9 August 2018
- journal article
- research article
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 29 (9) , 095011
Abstract
The Czech national standard of low gas flow is based on the dynamic gravimetry principle, defining the flow rate as the mass loss of gas from a pressure bottle which is continuously weighed. This weighing is performed in ambient atmosphere, which brings two problems. First, the buoyancy corrections are the main and unavoidable source of uncertainty. Second, condensation of the water vapor on the pressure bottle can occur, due to its cooling below dew point at higher flow rates. A weighing carried out in a hermetically closed atmosphere suppresses the problematic buoyancy effects. A weighing in a vacuum does the same, and also eliminates any danger of water condensation. The paper describes the hermetic and vacuum mode modifications together with the relevant uncertainty analyses.Keywords
Funding Information
- Ministry of Industry and Trade of Czech Republic
This publication has 14 references indexed in Scilit:
- Constant pressure primary flow standard for gas flows from 0.01cm3/min to 100cm3/min (0.007–74μmol/s)Flow Measurement and Instrumentation, 2014
- Final report on EURAMET.M.P-S12 — Bilateral supplementary comparison of the national pressure standards of CMI and INRIM in the range 300 Pa to 15 kPa of negative gauge pressureMetrologia, 2014
- Final report on EURAMET.M.P-K4.2010: Key and supplementary comparison of national pressure standards in the range 1 Pa to 15 kPa of absolute and gauge pressureMetrologia, 2014
- Perspectives of atmospheric reference leaks calibration by gravimetric methodMeasurement, 2013
- Calibration of laminar flow meters for process gasesFlow Measurement and Instrumentation, 2012
- Method of measuring the change in volume of a diaphragm bellows used in a volume displacer of a constant-pressure gas flowmeter (with a practical guide)Measurement, 2011
- An additional uncertainty of the throughput generated by the constant pressure gas flowmeterJournal of Physics: Conference Series, 2008
- An intercomparison of low flow gas facilities at eleven European laboratories using a Molbloc transfer package: EURAMET.MM.FF-S3 (EURAMET Project no 806)Metrologia, 2008
- The use of diaphragm bellows to construct a constant pressure gas flowmeter for the flow rate range 10−7 Pa m3 s−1to 10−1 Pa m3 s−1Metrologia, 2007
- Final report on the supplementary comparison Euromet.M.P-S2 (bilateral comparison) in the pressure range from 30 Pa to 7000 PaMetrologia, 2007