Optimization of electrocoagulation process parameters for enhancing phosphate removal in a biofilm-electrocoagulation system
Authors:
Open Access
- 5 April 2021
- journal article
- research article
- Published by IWA Publishing in Water Science & Technology
- Vol. 83 (10) , 2560-2574
Abstract
This study aimed to enhance the removal of phosphate in synthetic rural sewage by using a continuous electrocoagulation (EC) combined with biofilm process in an integrated system. Characteristic indexes of biofilm process effluent covering pH, dissolved oxygen (DO), suspended solids (SS), chemical oxygen demand (COD) and phosphate maintained a narrow fluctuation range and tended not readily to influence the phosphate removal of subsequent electrocoagulation. Three parameters including inter-electrode distance, current intensity and reaction time were selected to investigate the performance of enhancing phosphate removal. On the strength of single-factor tests, the Box-Behnken design (BBD) coupled with response surface methodology (RSM) was applied to investigate the individual and mutual interaction impacts of the major operating parameters and to optimize conditions. The optimum conditions were found to be inter-electrode distance of 1.8 cm, current density of 2.1 mA/cm2 and EC reaction time of 34 min, and phosphate removal efficiency of 90.24% was achieved along with less than 1 mg/L in case of periodic polarity switching mode, which raised removal efficiency by 10.10% and reduced operating cost by 0.13 CNY/g PO4− compared to non-switching mode. The combination of biofilm processing and electrocoagulation treatment was proven to be a valid and feasible method for enhancing phosphate removal.Keywords
Funding Information
- Key Technologies Research and Development Program (2018YFE0106400)
This publication has 34 references indexed in Scilit:
- Phosphorus removal from spiked municipal wastewater using either electrochemical coagulation or chemical coagulation as tertiary treatmentSeparation and Purification Technology, 2012
- Desirability function approach: A review and performance evaluation in adverse conditionsChemometrics and Intelligent Laboratory Systems, 2011
- Treatment of rinse water from zinc phosphate coating by batch and continuous electrocoagulation processesJournal of Hazardous Materials, 2010
- Human alteration of the global nitrogen and phosphorus soil balances for the period 1970–2050Global Biogeochemical Cycles, 2009
- Phosphate removal from source separated urine by electrocoagulation using iron plate electrodesWater Science & Technology, 2009
- Remediation of phosphate-contaminated water by electrocoagulation with aluminium, aluminium alloy and mild steel anodesJournal of Hazardous Materials, 2009
- Response surface methodology (RSM) as a tool for optimization in analytical chemistryTalanta, 2008
- Preliminary evaluation of the electrochemical and chemical coagulation processes in the post-treatment of effluent from an upflow anaerobic sludge blanket (UASB) reactorJournal of Environmental Management, 2007
- Conditions influencing the removal of phosphate from synthetic wastewater: influence of the ionic compositionDesalination, 2007
- Decolorization of basic dye solutions by electrocoagulation: An investigation of the effect of operational parametersJournal of Hazardous Materials, 2006