This section is under preparation and will be included in the next issue. To determine whether the position of the tip of an umbilical arterial catheter influences the frequency of ischemic events, aortic thrombosis, intraventricular hemorrhage, mortality or necrotising enterocolitis in newborn infants. Randomized and quasi randomized controlled trials of umbilical catheterization use were obtained from the following sources: 1. Effective Care of the Newborn Infant, edited by JC Sinclair and MB Bracken. 2. Medline Search using Melvyl Medline Plus and the keyword headings 'Umbilic#', 'Catheter#' and subject heading 'Infant, Newborn' 3. Search of personal data files Randomized trials in newborn infants of any birthweight or gestation. Comparison of high catheter placement with the tip above the diaphragm to a lower position just above the aortic bifurcation. Clinically important end points such as ischemic events or aortic thrombosis. Five randomized controlled trials and one alternate assignment study had sufficiently detailed data to allow interpretation. High placed umbilical artery catheters are associated with a lower incidence of clinical vascular complications, without an increase in any adverse sequelae. Intraventricular hemorrhage rates, death and necrotising enterocolitis are not more frequent with high compared to low catheters. There appears to be no evidence to support the use of low placed umbilical artery catheters. High catheters should be used exclusively.Keywords
This publication has 11 references indexed in Scilit:
- Umbilical artery catheters in the newborn: effects of position of the catheter tipCochrane Database of Systematic Reviews, 1999
- The association of heparin exposure with intraventricular hemorrhage among very low birth weight infants.1995
- Randomized trial of umbilical arterial catheter position: clinical outcomeActa Paediatrica, 1993
- Randomised trial of umbilical arterial catheter position: Doppler ultrasound findings.Archives of Disease in Childhood, 1992
- Aortic thrombosis after umbilical artery catheterization in neonates: prevalence of complications on long-term follow-up.American Journal of Roentgenology, 1991
- Sonographic detection of neonatal umbilical-artery thrombosis: clinical correlationAmerican Journal of Roentgenology, 1987
- NEONATAL HYPERTENSION APPEARS UNRELATED TO AORTIC CATHETER POSITIONPediatric Research, 1984
- UMBILICAL ARTERY CATHETERIZATION IN NEWBORNS I. Thrombosis in Relation to Catheter Type and PositionActa Paediatrica, 1979
- Low Positioning of Umbilical-Artery Catheters Increases Associated Complications in Newborn InfantsNew England Journal of Medicine, 1978
- Umbilical artery catheters: High, low, or noJournal of Perinatal Medicine, 1978