Temporal effects of cell adhesion on mechanical characteristics of the single chondrocyte
Authors:
- Bahman AnvariBahman Anvari
- Richard G. LebaronRLRichard G. Lebaron
- Kyriacos A. AthanasiouKAKyriacos A. Athanasiou
- 1 January 2003
- journal article
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 21 (1) , 88-95
Abstract
Cell adhesion to material surfaces is a fundamental phenomenon in tissue response to implanted devices, and an important consideration in tissue engineering. For example, elucidation of phenomena associated with adhesion of chondrocytes to biomaterials is critical in addressing the difficult problem of articular cartilage regeneration. The first objective of this study was to measure the mechanical adhesiveness characteristics of individual rabbit articular chondrocytes as a function of seeding time to provide further understanding of the cell adhesion process. The second objective was to quantify the force required to separate the plasma membrane from the underlying cytoskeleton as a function of seeding time. After culturing chondrocytes on glass coverslips for 1, 2, 4, 6 h, two biomechanical tests were performed on single chondrocytes: (i) mechanical adhesiveness measurement by the cytodetacher; and (ii) plasma membrane tether formation force measurement by optical tweezers. Cell mechanical adhesiveness increased from 231 ± 149 Pa at 1 h to 1085 ± 211 Pa at 6 h. The cell contact area with the substrata increased from 161 ± 52 μm2 at 1 h to 369 ± 105 μm2 at 6 h. The tether formation force increased from 232 ± 23 pN at 1 h to 591 ± 17 pN at 6 h. Moreover, fluorescence staining by rhodamine‐phalloidin demonstrated the process of actin spreading within the cytoskeleton from 0.5 to 6 h and allowed for measurement of cell height which was found to decrease from 12.3 ± 2.9 μm at 0.5 h to 6.2 ± 0.9 μm at 6 h.© 2002 Orthopaedic Research Society. Published by Elsevier Science Ltd. All rights reserved.Keywords
This publication has 23 references indexed in Scilit:
- Development of the cytodetachment technique to quantify mechanical adhesiveness of the single cellBiomaterials, 1999
- Energy of dissociation of lipid bilayer from the membrane skeleton of red blood cellsBiophysical Journal, 1997
- Stretching DNA with optical tweezersBiophysical Journal, 1997
- Micropipette suction for measuring piconewton forces of adhesion and tether formation from neutrophil membranesBiophysical Journal, 1996
- Deformation and flow of membrane into tethers extracted from neuronal growth conesBiophysical Journal, 1996
- Laser micromanipulators for biotechnology and genome researchJournal of Biotechnology, 1994
- Bead movement by single kinesin molecules studied with optical tweezersNature, 1990
- Optical trapping and manipulation of single cells using infrared laser beamsNature, 1987
- Red blood cells experience electrostatic repulsion but make molecular adhesions with glassBiophysical Journal, 1985
- Adhesion of human erythrocytes to glass: The nature of the interaction and the effect of serum and plasmaJournal of Cellular Physiology, 1971