Abstract
The article describes effects of sample conditions during its irradiation and electron paramagnetic resonance (EPR) measurements on the background (BG) and dosimetric EPR signals in bone. Intensity of the BG signal increased up to two to three times after crushing of bone to sub-millimetre grains. Immersion of samples in water caused about 50 % drop in intensity of the BG component followed by its regrowth in 1–2 months. Irradiation of bone samples produced an axial dosimetric EPR signal (radiation-induced signal) attributed to hydroxyapatite component of bone. This signal was stable and was not affected by water. In samples irradiated in dry conditions, EPR signal similar to the native BG was also generated by radiation. In samples irradiated in wet conditions, this BG-like component was initially much smaller than in bone irradiated as dry, but increased in time, reaching similar levels as in dry-irradiated samples. It is concluded that accuracy of EPR dosimetry in bones can be improved, if calibration of the samples is done by their irradiations in wet conditions.Keywords
This publication has 17 references indexed in Scilit:
- Physical dosimetric reconstruction of a radiological accident due to gammagraphy equipment that occurred in Dakar and Abidjan in summer 2006Radiation Measurements, 2008
- EPR dosimetry for actual and suspected overexposures during radiotherapy treatments in PolandRadiation Measurements, 2007
- BiodosEPR-2006 Meeting: Acute dosimetry consensus committee recommendations on biodosimetry applications in events involving uses of radiation by terrorists and radiation accidentsRadiation Measurements, 2007
- BiodosEPR-2006 consensus committee report on biodosimetric methods to evaluate radiation doses at long times after exposureRadiation Measurements, 2007
- The Third International Intercomparison on EPR Tooth Dosimetry: part 2, final analysisRadiation Protection Dosimetry, 2006
- The 3rd international intercomparison on EPR tooth dosimetry: Part 1, general analysisApplied Radiation and Isotopes, 2005
- ESR dosimetry of 89Sr- and 153Sm-in boneApplied Radiation and Isotopes, 2001
- The second international intercomparison on EPR tooth dosimetryRadiation Measurements, 2000
- Radiation dosimetry of an accidental overexposure using EPR spectrometry and imaging of human boneApplied Radiation and Isotopes, 1996
- Mechanically Induced Free Radicals in BoneNature, 1968