Prospective assessment of an artificial neural network for the detection of peripheral vascular disease from lower limb pulse waveforms
- 1 February 1995
- journal article
- Published by IOP Publishing in Physiological Measurement
- Vol. 16 (1) , 29-38
Abstract
The diagnostic performance of an artificial neural network pulse classification system for the detection of peripheral vascular disease was investigated prospectively. Lower limb photoelectric plethysmographic pulses, and Doppler ankle/brachial pressure index (ABPI) measurements (pre- and post-exercise) were obtained from 200 patients referred to a vascular investigation laboratory. A single toe pulse was processed and used as input data to a neural network which had been trained previously with a set of pulses from 100 legs. The neural network outputs represented the diagnostic arterial disease classifications defined by the ABPI. From the 200 patients entered prospectively, 266 legs were available for neural network assessment. A network sensitivity of 92% and specificity of 63% were achieved with a diagnostic accuracy of 80%. By using a higher confidence for the classification decision a small, but insignificant overall improvement was obtained. When a borderline classification was introduced 100% sensitivity and 100% negative predictive value were obtained, though 31% of legs were unclassifiable. Nevertheless, the very high sensitivity and negative predictive value could make this quick and simple technique the one of choice for the first stage in screening large numbers of subjects.Keywords
This publication has 10 references indexed in Scilit:
- Development of a neural network screening aid for diagnosing lower limb peripheral vascular disease from photoelectric plethysmography pulse waveformsPhysiological Measurement, 1993
- Review of neural network applications in medical imaging and signal processingMedical & Biological Engineering & Computing, 1992
- Basic Data Related to the Natural History of Intermittent ClaudicationAnnals of Vascular Surgery, 1989
- Repeatability of peripheral pulse measurements on ears, fingers and toes using photoelectric plethysmographyClinical Physics and Physiological Measurement, 1988
- The detection and progression of asymptomatic peripheral arterial diseaseBritish Journal of Surgery, 1983
- Standard exercise test to assess peripheral arterial disease.BMJ, 1980
- The relationship between ultrasound assessment and angiography in occlusive arterial disease of the lower limbBritish Journal of Surgery, 1975
- Response of Ankle Systolic Pressure to Leg Exercise in Mild or Questionable Arterial DiseaseNew England Journal of Medicine, 1972
- Ankle systolic pressure measurements in arterial disease affecting the lower extremitiesBritish Journal of Surgery, 1969
- Hepatic SurgeryAnnals of Surgery, 1965