Characteristics of the air-water counter current two-phase flow in a 1/30 scale of pressurized water reactor (PWR): Interfacial behavior and CCFL data
- 1 January 2016
- conference paper
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1737 (1) , 040015
Abstract
An experiment for investigating the flooding and deflooding phenomena in a complex system has been conducted. The liquid film behavior for the flooding and deflooding were studied under various superficial liquid velocities. The onset of flooding was observed at high superficial gas velocity when the superficial liquid velocity was low. On the other hand, for the high superficial liquid velocity, the flooding was initiated at the lower superficial gas velocity. In flooding experiment, it is obvious that the higher superficial gas velocity is needed than that of deflooding experiment. At the higher superficial liquid velocity, it is also found that the hysteresis is more significant than that of lower superficial liquid velocity.Keywords
This publication has 10 references indexed in Scilit:
- Experimental investigation of countercurrent flow limitation (CCFL) in a large-diameter hot-leg geometry: A detailed description of CCFL mechanisms, flow patterns and high-quality HSC imaging of the interfacial structure in a 1/3.9 scale of PWR geometryNuclear Engineering and Design, 2014
- Image-Processing-Based Study of the Interfacial Behavior of the Countercurrent Gas-Liquid Two-Phase Flow in a Hot Leg of a PWRScience and Technology of Nuclear Installations, 2012
- Experimental Characterisation of the Interfacial Structure during Counter-Current Flow Limitation in a Model of the Hot Leg of a PWRScience and Technology of Nuclear Installations, 2012
- CFD studies on the phenomena around counter-current flow limitations of gas/liquid two-phase flow in a model of a PWR hot legNuclear Engineering and Design, 2011
- A review of CCFL phenomenonAnnals of Nuclear Energy, 2011
- Air/Water Counter-Current Flow Experiments in a Model of the Hot Leg of a Pressurized Water ReactorJournal of Engineering for Gas Turbines and Power, 2009
- Study of countercurrent flow limitation in a horizontal pipe connected to an inclined oneNuclear Engineering and Design, 2005
- Effect of inclination angles and upper end conditions on the countercurrent flow limitation in straight circular pipesInternational Communications in Heat and Mass Transfer, 1998
- Two-phase countercurrent flow in a model of a pressurized water reactor hot legNuclear Engineering and Design, 1996
- Flooding in a horizontal pipe with bendInternational Journal of Multiphase Flow, 1996