The purpose of this work is to detect dynamic gas trapping in three dimensions during forced exhalation at isotropic high spatial resolution and high temporal resolution using hyperpolarized helium‐3 MRI. Ten subjects underwent hyperpolarized helium‐3 MRI and multidetector CT. MRI was performed throughout inspiration, breath‐hold, and forced expiration. A multiecho three‐dimensional projection acquisition was used to improve data collection efficiency and an iterative constrained reconstruction was implemented to improve signal to noise ratio (SNR) and increase robustness to motion. Two radiologists evaluated the dynamic MRI and breath‐held multidetector CT data for gas and air trapping, respectively. Phantom studies showed the proposed technique significantly improved depiction of moving objects compared to view‐sharing methods. Gas trapping was detected using MRI in five of the six asthmatic subjects who displayed air trapping with multidetector CT. Locations in disagreement were found to represent small to moderate regions of air trapping. The proposed technique provides whole‐lung three‐dimensional imaging of respiration dynamics at high spatial and temporal resolution and compares well to the current standard, multidetector CT. While multidetector CT can provide information about static regional air trapping, it is unable to depict dynamics in a setting more comparable to a spirometry maneuver and explore the longitudinal time evolution of the trapped regions. Magn Reson Med, 2009.Keywords
Funding Information
- National Institutes of Health (2T32-CA09206-26, R01-HL069116)
- Hartwell Foundation Individual Biomedical Engineering Research Award SBF
- GE Healthcare
- Sandler Program for Asthma Research
This publication has 43 references indexed in Scilit:
- Comparison of airway diameter measurements from an anthropomorphic airway tree phantom using hyperpolarized 3He MRI and high‐resolution computed tomographyMagnetic Resonance in Medicine, 2007
- Retrospective cine 3He ventilation imaging under spontaneous breathing conditions: a non‐invasive protocol for small‐animal lung function imagingNMR in Biomedicine, 2006
- Highly constrained backprojection for time‐resolved MRIMagnetic Resonance in Medicine, 2005
- Quantitative analysis of regional airways obstruction using dynamic hyperpolarized 3He MRI—Preliminary results in children with cystic fibrosisJournal of Magnetic Resonance Imaging, 2005
- k‐t BLAST and k‐t SENSE: Dynamic MRI with high frame rate exploiting spatiotemporal correlationsMagnetic Resonance in Medicine, 2003
- Airway Structural Alterations Selectively Associated with Severe AsthmaAmerican Journal of Respiratory and Critical Care Medicine, 2003
- Proceedings of the ATS Workshop on Refractory AsthmaAmerican Journal of Respiratory and Critical Care Medicine, 2000
- Ultraschnelle MRT der Lungenventilation mittels hochpolarisiertem Helium-3*RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2000
- Spirometric Reference Values from a Sample of the General U.S. PopulationAmerican Journal of Respiratory and Critical Care Medicine, 1999
- Detection of Bronchial and Arterial Obstruction by Continuous Gas Analysis from Individual Lobes and Segments of the LungThorax, 1960