Intraoperative optical coherence tomography imaging to identify parathyroid glands
- 5 December 2014
- journal article
- Published by Springer Nature in Surgical Endoscopy
- Vol. 29 (9) , 2698-2704
Abstract
Optical coherence tomography (OCT) is a non-invasive high-resolution imaging technique that permits characterization of microarchitectural features in real time. Previous ex vivo studies have shown that the technique is capable of distinguishing between parathyroid tissue, thyroid tissue, lymph nodes, and adipose tissue. The purpose of this study was to evaluate the practicality of OCT during open and minimally invasive parathyroid and thyroid surgery. During parathyroid and thyroid surgery, OCT images were generated from parathyroid glands, thyroid tissue, lymph nodes, and adipose tissue. The images were immediately assessed by the operating team using the previously defined criteria. Second, the OCT images were blinded with respect to their origin and analyzed by two investigators. Whenever possible the OCT findings were matched to the corresponding histology. A total of 227 OCT images from 27 patients undergoing open or minimally invasive thyroid or parathyroid surgery were analyzed. Parathyroid glands were correctly identified in 69.2 %, thyroid tissue in 74.5 %, lymph nodes in 37.5 %, and adipose tissue in 69.2 %. 43 OCT images (18.9 %) could not be allocated to one of the tissue types (Table 2). Sensitivity and specificity in distinguishing parathyroid tissue from the other entities were 69 % (63 true positive, 13 false negative findings, 15 images where an allocation was not possible) and 66 %, respectively (71 true negative, 9 false positive, 28 images where an assessment was not possible). OCT is capable of distinguishing between parathyroid, thyroid, and adipose tissue. An accurate differentiation between parathyroid tissue and lymph nodes was not possible. The disappointing results compared to the previous ex vivo study are related to problems handling the endoscopic probe intraoperatively. However, further refinement of this new technology may lead to OCT systems with higher resolution and intraoperative probes that are easier to handle.Keywords
This publication has 28 references indexed in Scilit:
- Systematic review of intravenous methylene blue in parathyroid surgeryBritish Journal of Surgery, 2012
- Intraoperative photodynamic detection of normal parathyroid glands using 5‐aminolevulinic acidThe Laryngoscope, 2011
- Optical coherence tomography for the diagnosis of cervical intraepithelial neoplasiaLasers in Surgery and Medicine, 2011
- Cellular and Functional Optical Coherence Tomography of the Human Retina The Cogan LectureInvestigative Ophthalmology & Visual Science, 2007
- Introducing Wolfgang Drexler, the 2007 Recipient of the Cogan AwardInvestigative Ophthalmology & Visual Science, 2007
- Optical coherence tomography: a review of clinical development from bench to bedsideJournal of Biomedical Optics, 2007
- Minimally invasive procedure for resection of a parathyroid adenoma: The role of preoperative high-resolution ultrasonographyJournal of Clinical Ultrasound, 2005
- Radioguided Parathyroidectomy Is Equally Effective for Both Adenomatous and Hyperplastic GlandsAnnals of Surgery, 2003
- Minimally invasive radioguided parathyroidectomy1Journal of the American College of Surgeons, 2000
- A Coefficient of Agreement for Nominal ScalesEducational and Psychological Measurement, 1960