Determination of glyphosate residue in maize and rice using a fast and easy method involving liquid chromatography–mass spectrometry (LC/MS/MS)
Authors:
- 12 January 2019
- journal article
- research article
- Published by Taylor & Francis in Journal of Environmental Science and Health, Part B
- Vol. 54 (3) , 205-210
Abstract
A fast and easy method was developed for the determination of glyphosate in maize and rice by using liquid chromatography triple quadrupole mass spectrometry with a Dionex Ion Pack column and phosphate buffer mobile phase. Samples were extracted with an acidified methanol solution. An isotope-labeled internal standard was added to the sample before extraction to ensure accurate tracking and quantification. The method’s performance was evaluated through a series of assessments to determine the accuracy, precision, linearity, matrix effect, limit of detection (LOD), and limit of quantification (LOQ). The mean recoveries for both matrices were within 70–105% at three fortification levels, including the LOQ. The precision for replicates was R2=0.9982) was obtained over the concentration range of 0.01–1.5 mg kg−1. The LOD was determined to be 0.002 mg kg−1 for rice and 0.004 mg kg−1 for maize. The LOQ was 0.01 mg kg−1 for both maize and rice. Due to its versatility, the proposed method could be considered useful for the determination of glyphosate in cereals in routine analysis.Keywords
This publication has 14 references indexed in Scilit:
- Analysis of Glyphosate and Aminomethylphosphonic Acid in Nutritional Ingredients and Milk by Derivatization with Fluorenylmethyloxycarbonyl Chloride and Liquid Chromatography–Mass SpectrometryJournal of Agricultural and Food Chemistry, 2015
- Improvements in the analytical methodology for the residue determination of the herbicide glyphosate in soils by liquid chromatography coupled to mass spectrometryJournal of Chromatography A, 2013
- Study of liquid chromatography/electrospray ionization mass spectrometry matrix effect on the example of glyphosate analysis from cerealsRapid Communications in Mass Spectrometry, 2011
- Solid‐phase extraction and residue determination of glyphosate in apple by ion‐pairing reverse‐phase liquid chromatography with pre‐column derivatizationJournal of Separation Science, 2009
- An alternative and fast method for determination of glyphosate and aminomethylphosphonic acid (AMPA) residues in soybean using liquid chromatography coupled with tandem mass spectrometryRapid Communications in Mass Spectrometry, 2009
- Ultratrace-level determination of glyphosate, aminomethylphosphonic acid and glufosinate in natural waters by solid-phase extraction followed by liquid chromatography–tandem mass spectrometry: performance tuning of derivatization, enrichment and detectionAnalytical and Bioanalytical Chemistry, 2008
- Determination of glyphosate and AMPA in surface and waste water using high-performance ion chromatography coupled to inductively coupled plasma dynamic reaction cell mass spectrometry (HPIC–ICP–DRC–MS)Analytical and Bioanalytical Chemistry, 2008
- Direct determination of glyphosate using hydrophilic interaction chromatography with coulometric detection at copper microelectrodeAnalytica Chimica Acta, 2007
- Re-evaluation of glyphosate determination in water by liquid chromatography coupled to electrospray tandem mass spectrometryJournal of Chromatography A, 2006
- Determination of glyphosate and related compounds using HPLC with tris(2,2′-bipyridyl)ruthenium(II) electrogenerated chemiluminescence detectionAnalytica Chimica Acta, 1997