Investigation of the relationship between heart rate measured automatically at different time intervals using the 3M littmann 3200 electronic stethoscope and heart rate measured by electrocardiography
Author:
Open Access
- 14 October 2026
- journal article
- Published by Journal of Advances in VetBio Science and Techniques in Journal of Advances in VetBio Science and Techniques
- No. 3,p. 280-286
Abstract
Cardiac auscultation is an indispensable method in the examination of cats. With a traditional stethoscope, heart murmurs, gallop rhythms, and heart rate (HR) may not always be accurately assessed because of ambient noise interference. However, electronic stethoscopes (ESs) provide more uniform and amplified acoustic signals, allowing more accurate identification of physiological and pathological heart sounds during auscultation. The aim of this study was to determine the agreement, differences, and correlation between HR automatically measured using a 3M Littmann 3200 ES over 15-, 30-, and 60-second intervals and HR obtained by electrocardiography (ECG) in 34 healthy cats of various breeds, ages, and sexes. To this end, intraclass correlation coefficient (ICC), Bland–Altman, and Spearman’s correlation analyses were performed. ICC analysis showed moderate agreement between ECG and ES at the 15- and 60-second measurement intervals (r = 0.661, P < 0.001; r = 0.700, P < 0.001, respectively), whereas the 30-second interval demonstrated higher agreement (r = 0.812, P < 0.001). According to Bland-Altman analysis, 30-second HR measurements by ES showed the closest agreement with ECG (bias = 5.03; 95% limits of agreement = -34.34 to 44.40), compared to 15 seconds (bias = 9.41; -48.34 to 67.16) and 60 seconds (bias = 9.06; -41.88 to 59.99). In conclusion, this study demonstrates that 30-second measurements obtained with the 3M Littmann 3200 ES provide heart rate measurements comparable to those obtained by ECG in healthy cats.Keywords
Funding Information
- This study was conducted without any grants or funding from private or public institutions.
This publication has 27 references indexed in Scilit:
- Clinical evaluation of a digital stethoscope with simultaneous phonocardiography and electrocardiography in catsVeterinary Research Communications, 2024
- Evaluation of a digital stethoscope for electrocardiographic recording in donkeys: Preliminary resultsJournal of Equine Veterinary Science, 2024
- Evaluation of a new smartphone-based digital stethoscope featuring phonocardiography and electrocardiography in dogs and catsThe Veterinary Journal, 2023
- Determination of heart rate variability with an electronic stethoscopeClinical Autonomic Research, 2012
- Comparison of auscultatory and echocardiographic findings in healthy adult catsJournal of Veterinary Cardiology, 2010
- Assessment of Autonomic Function in Cardiovascular DiseaseJACC, 2008
- The reliability of short-term measurements of heart rate variabilityInternational Journal of Cardiology, 2005
- Clinical Comparison of Acoustic and Electronic Stethoscopes and Design of a New Electronic StethoscopeThe American Journal of Cardiology, 1998
- Bedside measurement of systolic and diastolic time intervals using the stethometerCardiovascular Research, 1977
- EXAMINATION OF THE HEART: AN INVESTIGATION INTO VARIATION1American Journal of Epidemiology, 1967