Meta-Analysis of 40- and 64-MDCT Angiography for Assessing Coronary Artery Stenosis

Authors:

Abstract
OBJECTIVE. The purpose of our study was to assess the diagnostic performance of thin-slice (≤ 0.625 mm) MDCT coronary angiography compared with invasive coronary angiography for the detection of significant (≥ 50%) stenosis.MATERIALS AND METHODS. Twenty-two articles on 40- and 64-MDCT coronary angiography were included. Sensitivity and specificity were calculated on a per-patient and per-segment basis; in addition, proximal versus distal segments were evaluated. The effect of nonevaluable patients, nonevaluable segments, and disease prevalence on diagnostic performance was assessed.RESULTS. Pooled sensitivity on a patient level was 97.7% ([95% CI] 96.2–98.7%) and specificity 91.0% (88.5–93.1%). Pooled sensitivity on a segmental level was 90.8% (89.0–92.4%) and specificity 95.7% (95.2–96.1%); for proximal segments, respectively, 94.2% (92.3–95.7%) and 94.1% (93.4–94.8%), and for distal segments 84.8% (81.1–88.0%) and 96.9% (96.4–97.4%). If nonevaluable MDCT investigations were included, the per-patient spe...