Vibration Control of the Wind-Excited 76-Story Benchmark Building by Liquid Column Vibration Absorbers
- 1 April 2004
- journal article
- Published by American Society of Civil Engineers (ASCE) in Journal of Engineering Mechanics
- Vol. 130 (4) , 478-485
Abstract
A study has been undertaken on the effectiveness of using liquid column vibration absorbers (LCVAs), in the suppression of wind-induced motion of the 76-story benchmark building. Much work has been undertaken on the behavior of the LCVA on an experimental level and its benefits have been demonstrated for wind-induced vibration control on a full-scale communications tower in Sydney, Australia, with a further installation being made on the “One Wall Center Building” Vancouver, Canada. The behavior of the LCVA has also been investigated numerically by use of computational fluid dynamics, and its potential has been illustrated in controlling a five-story building model. In this study, the LCVA adopted is composed of four identical columns of water. Initially, the performance of the LCVA is assessed without the inclusion of additional damping enhancing mechanisms. Subsequently, the same LCVA is considered with the inclusion of orifice plates, allowing a direct comparison of the two strategies. In order to addr...Keywords
This publication has 4 references indexed in Scilit:
- VIBRATION CONTROL OF A FIVE STOREY BENCHMARK BUILDING EXCITED BY EARTHQUAKE USING LIQUID COLUMN VIBRATION ABSORBERS2002
- DAMPING ENHANCEMENT OF LIQUID COLUMN VIBRATION ABSORBERS BY USE OF ORIFICE PLATESThe Proceedings of the International Conference on Motion and Vibration Control, 2002
- On spurious behavior of CFD simulationsInternational Journal for Numerical Methods in Fluids, 1999
- Effectiveness of tuned liquid column dampers for vibration control of towersEngineering Structures, 1995