Quantitative assessment of disease markers using the naked eye: point-of-care testing with gas generation-based biosensor immunochromatographic strips
Open Access
- 17 May 2019
- journal article
- research article
- Published by Springer Nature in Journal of Nanobiotechnology
- Vol. 17 (1) , 1-10
Abstract
Immunochromatographic strips (ICSs) are a practical tool commonly used in point-of-care testing (POCT) applications. However, ICSs that are currently available have low sensitivity and require expensive equipment for quantitative analysis. These limitations prohibit their extensive use in areas where medical resources are scarce. We developed a novel POCT platform by integrating a gas generation biosensor with Au@Pt Core/Shell nanoparticle (Au@PtNPs)-based ICSs (G-ICSs). The resulting G-ICSs enabled the convenient and quantitative assessment of a target protein using the naked eye, without the need for auxiliary equipment or complicated computation. To assess this platform, C-reactive protein (CRP), a biomarker commonly used for the diagnosis of acute, infectious diseases was chosen as a proof-of-concept test. The linear detection range (LDR) of the G-ICSs for CRP was 0.05–6.25 μg/L with a limit of detection (LOD) of 0.041 μg/L. The G-ICSs had higher sensitivity and wider LDR when compared with commonly used AuNPs and fluorescent-based ICSs. When compared with results from a chemiluminescent immunoassay, G-ICS concordance rates for CRP detection in serum samples ranged from 93.72 to 110.99%. These results demonstrated that G-ICSs have wide applicability in family diagnosis and community medical institutions, especially in areas with poor medical resources.Keywords
Funding Information
- Guangzhou Science and Technology Project (201604020006)
This publication has 31 references indexed in Scilit:
- Multiplexed immunochromatographic test strip for time-resolved chemiluminescent detection of pesticide residues using a bifunctional antibodyBiosensors and Bioelectronics, 2017
- Pt@AuNPs integrated quantitative capillary-based biosensors for point-of-care testing applicationBiosensors and Bioelectronics, 2016
- An immunochromatographic biosensor combined with a water-swellable polymer for automatic signal generation or amplificationBiosensors and Bioelectronics, 2016
- Membrane-based lateral flow immunochromatographic strip with nanoparticles as reporters for detection: A reviewBiosensors and Bioelectronics, 2016
- Lateral Flow Immunoassays – from Paper Strip to Smartphone TechnologyElectroanalysis, 2015
- A fluorescent polymer dots positive readout fluorescent quenching lateral flow sensor for ractopamine rapid detectionAnalytica Chimica Acta, 2015
- Au@Pt Nanoparticle Encapsulated Target‐Responsive Hydrogel with Volumetric Bar‐Chart Chip Readout for Quantitative Point‐of‐Care TestingAngewandte Chemie, 2014
- A novel fluorescence-quenching immunochromatographic sensor for detection of the heavy metal chromiumBiosensors and Bioelectronics, 2013
- Colloidal gold nanoparticle probe-based immunochromatographic assay for the rapid detection of chromium ions in water and serum samplesAnalytica Chimica Acta, 2012
- A novel immunochromatographic electrochemical biosensor for highly sensitive and selective detection of trichloropyridinol, a biomarker of exposure to chlorpyrifosBiosensors and Bioelectronics, 2011