Ultracapacitor storage for a 50t capacity gantry crane
Authors:
- A. Di NapoliANA. Di Napoli
- A. NdokajANA. Ndokaj
- 1 September 2012
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2014-2018
Abstract
This paper presents, for a system consisting of a gantry crane, the sizing of an Ultracapacitor (UC) based storage sytem, and its performance test using a simulated model of the system considered as a multi-axis drive. Preliminary examination of different operating processes has been done. For each proccess were considered the different drives refered to the toughest conditions, and the diagrams of torque, power and energy were built for each of them. Two different approches were used for the UCs sizing. The first approach consists on considering the peak power during each operating proccess and consequently the energy furnished by the system during these power peaks. The second approach consists on considering the energy of the lifting process (UCs recharge).Keywords
This publication has 5 references indexed in Scilit:
- Power flow analysis for plug in hybrid electric vehicles2010
- Energy Storage and Power Management for Typical 4Q-LoadIEEE Transactions on Industrial Electronics, 2009
- Control technique and operation strategy of PM generators in hybrid vehicles2008
- Sizing ultracapacitors for hybrid electric vehicles2005
- Ultracapacitor-based ride-through system for adjustable speed drives applied to critical process2004