Determination of Ethanol Based on Polarographic Catalytic Current of Sulfate Radical Anion Using Ethanol as Catalyst

Authors:
  • JSJunfeng Song
    Junfeng Song
  • HFHuafeng Fu
    Huafeng Fu
  • WGWei Guo
    Wei Guo

Abstract
A new method for the determination of ethanol is proposed based on the catalytic current of sulfate radical anion SO4 −. In 0.1 mol/L KH2PO4–Na2HPO4 buffer (pH5.6±0.1)–1.6×10−2 mol/L K2S2O8 solution, the first order derivative peak current is proportional to ethanol concentration in the range of 1×10−4∼9×10−4 (r = 0.9998). The limit of detection is 6×10−5 mol/L. The proposed method is applied to determine ethanol directly content in ardent spirits. The fundamental principle of the proposed method is that ethanol is oxidized by sulfate radical anion SO4 − electrogenerated on the electrode surface to ethanol α-radical, and the reduction of the ethanol α-radical produces a polarographic reduction wave.

This publication has 7 references indexed in Scilit: