Final 5‐Year Report of the Randomized BIO‐RESORT Trial Comparing 3 Contemporary Drug‐Eluting Stents in All‐Comers
Authors:
- Eline H. PloumenEPEline H. Ploumen
- Tineke H. PinxterhuisTPTineke H. Pinxterhuis
- Paolo ZoccaPZPaolo Zocca
- Peter W. DansePDPeter W. Danse
- Carl E. SchotborghCSCarl E. Schotborgh
- Martijn ScholteMSMartijn Scholte
- R. Melvyn Tjon Joe GinRGR. Melvyn Tjon Joe Gin
- Samer SomiSSSamer Somi
- K. Gert van HouwelingenKHK. Gert van Houwelingen
Open Access
- 8 November 2022
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 11 (22) , e026041
Abstract
Background: In a previous trial, higher 5‐year mortality was observed following treatment with biodegradable polymer Orsiro sirolimus‐eluting stents (SES). We assessed 5‐year safety and efficacy of all‐comers as well as patients with diabetes treated with SES or Synergy everolimus‐eluting stents (EES) versus durable polymer Resolute Integrity zotarolimus‐eluting stents (ZES). Methods and Results: The randomized BIO‐RESORT (Comparison of Biodegradable Polymer and Durable Polymer Drug‐Eluting Stents in an All Comers Population) trial enrolled 3514 all‐comer patients at 4 Dutch cardiac centers. Patients aged ≥18 years who required percutaneous coronary intervention were eligible. Participants were stratified for diabetes and randomized to treatment with SES, EES, or ZES (1:1:1). The main end point was target vessel failure (cardiac mortality, target vessel myocardial infarction, or target vessel revascularization). Five‐year follow‐up was available in 3183 of 3514 (90.6%) patients. The main end point target vessel failure occurred in 142 of 1169 (12.7%) patients treated with SES, 130 of 1172 (11.6%) treated with EES, versus 157 of 1173 (14.1%) treated with ZES (hazard ratio [HR], 0.89 [95% CI, 0.71–1.12], P log‐rank =0.31; and HR, 0.82 [95% CI, 0.65–1.04], P log‐rank =0.10, respectively). Individual components of target vessel failure showed no significant between‐stent difference. Very late definite stent thrombosis rates were low and similar (SES, 1.1%; EES, 0.6%; ZES, 0.9%). In patients with diabetes, target vessel failure did not differ significantly between stent‐groups (SES, 19.8%; EES, 19.2%; versus ZES, 21.1% [ P log‐rank =0.69 and P log‐rank =0.63]). Conclusions: Orsiro SES, Synergy EES, and Resolute Integrity ZES showed similar 5‐year outcomes of safety and efficacy, including mortality. A prespecified stent comparison in patients with diabetes also revealed no significant differences in 5‐year clinical outcomes. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT01674803.Keywords
This publication has 23 references indexed in Scilit:
- Five-Year Outcome After Implantation of Zotarolimus- and Everolimus-Eluting Stents in Randomized Trial Participants and Nonenrolled Eligible PatientsJAMA Cardiology, 2017
- Very thin strut biodegradable polymer everolimus-eluting and sirolimus-eluting stents versus durable polymer zotarolimus-eluting stents in allcomers with coronary artery disease (BIO-RESORT): a three-arm, randomised, non-inferiority trialThe Lancet, 2016
- Randomized Trial of Polymer-Free Sirolimus- and Probucol-Eluting Stents Versus Durable Polymer Zotarolimus-Eluting StentsJACC: Cardiovascular Interventions, 2016
- Five-year outcomes from a trial of three limus-eluting stents with different polymer coatings in patients with coronary artery disease: final results from the ISAR-TEST 4 randomised trialEuroIntervention, 2016
- Impact of Diabetic Status on Outcomes After Revascularization With Drug-Eluting Stents in Relation to Coronary Artery Disease ComplexityCirculation: Cardiovascular Interventions, 2016
- Impact of Coronary Lesion Complexity on Drug-Eluting Stent Outcomes in Patients With and Without Diabetes MellitusJACC, 2014
- Improved Safety and Reduction in Stent Thrombosis Associated With Biodegradable Polymer-Based Biolimus-Eluting Stents Versus Durable Polymer-Based Sirolimus-Eluting Stents in Patients With Coronary Artery DiseaseJACC: Cardiovascular Interventions, 2013
- Clinical and angiographic experience with a third-generation drug-eluting Orsiro stent in the treatment of single de novo coronary artery lesions (BIOFLOW-I): a prospective, first-in-man studyEuroIntervention, 2013
- Myocardial infarction adjudication in contemporary all-comer stent trials: balancing sensitivity and specificityEuroIntervention, 2010
- Clinical End Points in Coronary Stent TrialsCirculation, 2007