Fluoroscopic Overlay of Landmarks from Pre-procedural CT Images after 2D3D Image Fusion to Optimize Trans-septal Access During Percutaneous Mitral Interventions
Open Access
- 1 August 2018
- journal article
- research article
- Published by Elsevier in Structural Heart
- Vol. 2 (5) , 433-438
Abstract
Background: Recent evolution of transcatheter mitral devices and interventions has mandated the need for further optimizing trans-septal access technique with respect to its precise location and distance from the mitral valve annulus. Methods: Based on the individual procedural context, “ideal” trans-septal access site was planned in multi-slice CT images. In addition, relevant landmarks such as mitral annulus, para-valvular leak site, left atrial appendage (LAA) ostium were electronically marked. CT-fluoroscopy image fusion was performed using a commercially available software after acquiring two fluoroscopic images at-least 30° apart. Manual refinement of image fusion was performed by aligning structures such as a prosthetic valve or mitral annular calcification, when necessary. Results: Between June and October 2016, a total of five procedures (n = 3 Mitral paravalvular leak, n = 2 Mitraclip®) were performed in four patients using trans-esophageal echocardiography (TEE) and CT image fusion guidance. Fluoroscopic overlay of landmarks including the optimal trans-septal puncture site from pre-procedural CT images was feasible in all five procedures. Median time for CT-fluoroscopy image fusion was 4:08 minutes. Median time for left atrial access was 7:00 minutes. Median (range) fluoroscopy time and total procedural dose-area-product were 29.9 minutes (15.1–77.5) and 16,638 microGy-m2 (9464–18,990) respectively. Conclusion: In addition to real-time TEE imaging, pre-procedural CT planning, image fusion and overlay of relevant landmarks enhances 2D fluoroscopy and provided additional 3D image guidance. Seamless integration of such multi-modality image information can help further optimize steps such as trans-septal access for complex mitral interventions.Keywords
This publication has 11 references indexed in Scilit:
- Three-dimensional image fusion guidance of percutaneous pulmonary valve implantation to reduce radiation exposure and contrast dose: A comparison with traditional two-dimensional and three-dimensional rotational angiographic guidanceNetherlands Heart Journal, 2016
- Echocardiographic and Fluoroscopic Fusion Imaging for Procedural Guidance: An Overview and Early Clinical ExperienceJournal of the American Society of Echocardiography, 2016
- Different transseptal puncture for different procedures: Optimization of left atrial catheterization guided by transesophageal echocardiographyAnnals of Cardiac Anaesthesia, 2016
- Use of Computed Tomography to Guide Mitral InterventionsInterventional Cardiology Clinics, 2015
- Transseptal access for MitraClip® procedures using surgical diathermy under echocardiographic guidanceEuroIntervention, 2012
- A review of 3D/2D registration methods for image-guided interventionsMedical Image Analysis, 2012
- Utility of Combined Two-Dimensional and Three-Dimensional Transesophageal Imaging for Catheter-Based Mitral Valve Clip Repair of Mitral RegurgitationJournal of the American Society of Echocardiography, 2011
- Localization of fossa ovalis and Brockenbrough needle prior to left atrial ablation using three-dimensional mapping with EnSite Fusion™Journal of Interventional Cardiac Electrophysiology, 2010
- Emerging Applications for Transseptal Left Heart CatheterizationJACC, 2008
- Clinical application of transvenous mitral commissurotomy by a new balloon catheterThe Journal of Thoracic and Cardiovascular Surgery, 1984