Intraoperative Computed Tomography Scan for Orbital Fracture Reconstruction
Authors:
- Soo Ching KhooSKSoo Ching Khoo
- Syed NabilSNSyed Nabil
- Rifqah NordinRNRifqah Nordin
- Tan Huann LanTLTan Huann Lan
- Rama Krsna RajandramRRRama Krsna Rajandram
- Jothi Raamahlingam RajaranJRJothi Raamahlingam Rajaran
- 1 October 2019
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Craniofacial Surgery
- Vol. 30 (7) , 2159-2162
Abstract
Orbital fractures pose specific challenge in its surgical management. One of the greatest challenges is to obtain satisfactory reconstruction by correct positioning of orbital implant. Intraoperative computed tomography (CT) scan may facilitate this procedure. The aim of this study was to describe the early use of intraoperative CT in orbital fractures repair in our center. The authors assessed the revision types and rates that have occurred with this technique. With the use of pre-surgical planning, optical intraoperative navigation, and intraoperative CT, the impact of intraoperative CT on the management of 5 cases involving a total number of 14 orbital wall fractures were described. There were 6 pure orbital blowout wall fractures reconstructed, involving both medial and inferior wall of the orbit fracturing the transition zone and 8 impure orbital wall fractures in orbitozygomaticomaxillary complex fracture. 4 patients underwent primary and 1 had delayed orbital reconstruction. Intraoperative CT resulted in intraoperative orbital implant revision, following final navigation planning position, in 40% (2/5) of patients or 14% (2/14) of the fractures. In revised cases, both implant repositioning was conducted at posterior ledge of orbit. Intraoperative CT confirmed true to original reconstruction of medial wall, inferior wall and transition zone of the orbit. Two selected cases were illustrated. In conclusion, intraoperative CT allows real-time assessment of fracture reduction and immediate orbital implant revision, especially at posterior ledge. As a result, no postoperative imaging was indicated in any of the patients. Long-term follow-ups for orbital fracture patients managed with intraoperative CT is suggested.Keywords
This publication has 22 references indexed in Scilit:
- Retrospective analysis of 301 patients with orbital floor fractureJournal of Cranio-Maxillofacial Surgery, 2015
- Intraoperative 3-dimensional imaging (O-arm) for assessment of pedicle screw position: Does it prevent unacceptable screw placement?International Journal of Spine Surgery, 2012
- Intraoperative cone beam computed tomography in the management of facial fracturesInternational Journal of Oral and Maxillofacial Surgery, 2012
- Comparison of Intraoperative Portable CT Scanners in Skull Base and Endoscopic Sinus Surgery: Single Center Case SeriesJournal of Neurological Surgery Part B: Skull Base, 2011
- Real-time Intraoperative Computed Tomography Assessment of Quality of Permanent Interstitial Seed Implantation for Prostate CancerUrology, 2010
- O-Arm Surgical Imaging SystemSeminars in Spine Surgery, 2008
- Clinical indications and perspectives for intraoperative cone-beam computed tomography in oral and maxillofacial surgeryOral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology, 2007
- Computer-assisted reconstruction of orbital floor based on cone beam tomographyBritish Journal of Oral and Maxillofacial Surgery, 2007
- Intraoperative imaging of zygomaticomaxillary complex fractures using a 3D C-arm systemInternational Journal of Oral and Maxillofacial Surgery, 2005
- Intraoperative computed tomography to facilitate repair of orbitozygomatic fracturesOperative Techniques in Otolaryngology-Head and Neck Surgery, 2002