The Feasibility and Reliability of Upper Arm–Worn Apple Watch Heart Rate Monitoring for Surgeons During Surgery: Observational Study (Preprint)
Preprint
- 16 July 2023
- preprint
- Published by JMIR Publications Inc. in JMIR Preprints
Abstract
BACKGROUND Health care professionals, particularly those in surgical settings, face high stress levels, impacting their well-being. Traditional monitoring methods, like using Holter electrocardiogram monitors, are impractical in the operating room, limiting the assessment of physicians’ health. Wrist-worn heart rate monitors, like the Apple Watch, offer promise but are restricted in surgeries due to sterility issues. OBJECTIVE This study aims to assess the feasibility and accuracy of using an upper arm–worn Apple Watch for heart rate monitoring during robotic-assisted surgeries, comparing its performance with that of a wrist-worn device to establish a reliable alternative monitoring site. METHODS This study used 2 identical Apple Watch Series 8 devices to monitor the heart rate of surgeons during robotic-assisted surgery. Heart rate data were collected from the wrist-worn and the upper arm–worn devices. Statistical analyses included calculating the mean difference and SD of difference between the 2 devices, constructing Bland-Altman plots, assessing accuracy based on mean absolute error and mean absolute percentage error, and calculating the intraclass correlation coefficient. RESULTS The mean absolute errors for the whole group and for participants A, B, C, and D were 3.63, 3.58, 2.70, 3.93, and 4.28, respectively, and the mean absolute percentage errors were 3.58%, 3.34%, 2.42%, 4.58%, and 4.00%, respectively. Bland-Altman plots and scatter plots showed no systematic error when comparing the heart rate measurements obtained from the upper arm–worn and the wrist-worn Apple Watches. The intraclass correlation coefficients for participants A, B, C, and D were 0.559, 0.651, 0.508, and 0.563, respectively, with a significance level of P<.001, indicating moderate reliability. CONCLUSIONS The findings of this study suggest that the upper arm is a viable alternative site for monitoring heart rate during surgery using an Apple Watch. The agreement and reliability between the measurements obtained from the upper arm–worn and the wrist-worn devices were good, with no systematic error and a high level of accuracy. These findings have important implications for improving data collection and management of the physical and mental demands of operating room staff during surgery, where wearing a watch on the wrist may not be feasible.Keywords
All Related Versions
- Published version: JMIR Human Factors, 10, e50891.
This publication has 17 references indexed in Scilit:
- Accuracy of Apple Watch Measurements for Heart Rate and Energy Expenditure in Patients With Cardiovascular Disease: Cross-Sectional StudyJMIR mHealth and uHealth, 2019
- Physician burnout: contributors, consequences and solutionsJournal of Internal Medicine, 2018
- Number of recent stressful life events and incident cardiovascular disease: Moderation by lifetime depressive disorderJournal of Psychosomatic Research, 2017
- Accuracy in Wrist-Worn, Sensor-Based Measurements of Heart Rate and Energy Expenditure in a Diverse CohortJournal of Personalized Medicine, 2017
- A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability ResearchJournal of Chiropractic Medicine, 2016
- Heart Rate, Life Expectancy and the Cardiovascular System: Therapeutic ConsiderationsCardiology, 2015
- Burnout and Satisfaction With Work-Life Balance Among US Physicians Relative to the General US PopulationArchives of internal medicine (1960), 2012
- Life and Death: Metabolic Rate, Membrane Composition, and Life Span of AnimalsPhysiological Reviews, 2007
- Heart-Rate Profile during Exercise as a Predictor of Sudden DeathNew England Journal of Medicine, 2005
- HEART RATE AS A PROGNOSTIC FACTOR FOR CORONARY HEART DISEASE AND MORTALITY: FINDINGS IN THREE CHICAGO EPIDEMIOLOGIC STUDIESAmerican Journal of Epidemiology, 1980