Fetal-type posterior communicating artery increases hemodynamic stress in posterior communicating artery bifurcation aneurysms: a CFD-based analysis
Authors:
- Roland SchwabRSRoland Schwab
- Rebecca JaniszewskiRJRebecca Janiszewski
- Erelle FuchsEFErelle Fuchs
- Maximilian ThormannMTMaximilian Thormann
- Belal NeyaziBNBelal Neyazi
- Vanessa Magdalena SwiatekVSVanessa Magdalena Swiatek
- I. Erol SandalciogluISI. Erol Sandalcioglu
- Philipp BergPBPhilipp Berg
- Daniel BehmeDBDaniel Behme
- Samuel VoßSVSamuel Voß
- Janneck StahlJSJanneck Stahl
Open Access
- 20 September 2025
- journal article
- research article
- Published by Springer Nature in Neuroradiology
- Vol. 67 (9) , 2471-2481
Abstract
Backround: The flow characteristics of bifurcation aneurysms in the posterior communicating artery (PCOM) have rarely been studied. The likelihood of a complete PCOM aneurysm occlusion after endovascular treatment is reduced with the presence of a fetal posterior communicating artery (fPCOM). As a result, anatomical variations in PCOM aneurysms represent a major challenge for the endovascular treatment. This study addresses hemodynamic variations in PCOM aneurysms of either fetal or adult type. Methods: 3D-DSA data of 14 patients with bifurcation aneurysms located in the PCOM junction were collected. Nine patients presented with a fPCOM and five patients an adult PCOM (aPCOM). Patient-specific 3D models containing at least one bifurcation distal the aneurysm in the anterior circulation as well as the PCOM itself were extracted using image-based blood flow simulations. Seven hemodynamic parameters were calculated for all aneurysm models to characterize the intra-aneurysmal blood flow. The PCOM outflow was artificially varied to represent both fPCOM and aPCOM conditions for each model resulting in 28 simulations. Results: Fetal‑type PCOM showed higher intra‑aneurysmal mean velocity (median 0.09 vs. 0.06 m/s), maximum velocity (0.17 vs. 0.14 m/s), averaged wall shear stress (1.67 vs. 1.27 Pa), neck inflow rate (40.9 vs. 22.4 ml/min), and inflow concentration index (0.56 vs. 0.40), with lower pulsatility index (1.73 vs. 1.89). Those differences were significant whereas mean oscillatory shear index did not differ significantly. Conclusion: The presence of anatomical variations affects the hemodynamic parameters of PCOM bifurcation aneurysms. In particular, the presence of an fPCOM has an unfavorable effect on the intra-aneurysmal flow dynamics.Keywords
Funding Information
- Universitätsklinikum Magdeburg
This publication has 31 references indexed in Scilit:
- Impact of workflow variability on image-based intracranial aneurysm hemodynamicsComputers in Biology and Medicine, 2025
- Hemodynamic differences of posterior communicating artery aneurysms between adult and fetal types of posterior cerebral arteryActa Neurochirurgica, 2023
- Fetal-type posterior cerebral artery and association of rupture in posterior communicating artery aneurysms: A systematic review and meta-analysisClinical Neurology and Neurosurgery, 2023
- Integrating computational fluid dynamics data into medical image visualization workflows via DICOMInternational Journal of Computer Assisted Radiology and Surgery, 2022
- Risk factors for recurrence after coil embolization for internal carotid artery-posterior communicating artery aneurysmsInterdisciplinary Neurosurgery, 2021
- Flow-splitting-based computation of outlet boundary conditions for improved cerebrovascular simulation in multiple intracranial aneurysmsInternational Journal of Computer Assisted Radiology and Surgery, 2019
- Semiautomatic neck curve reconstruction for intracranial aneurysm rupture risk assessment based on morphological parametersInternational Journal of Computer Assisted Radiology and Surgery, 2018
- Morphometry and hemodynamics of posterior communicating artery aneurysms: Ruptured versus unrupturedJournal of Biomechanics, 2018
- Change in aneurysmal flow pulsatility after flow diverter treatmentComputerized Medical Imaging and Graphics, 2016
- Hemodynamic analysis of intracranial aneurysms with moving parent arteries: Basilar tip aneurysmsInternational Journal for Numerical Methods in Biomedical Engineering, 2010