Fault detection and reconfiguration strategy for ANPC converters
Authors:
- 1 September 2012
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. DS1b.17-1
Abstract
Active Neutral Point Clamped (ANPC) topology is an optimization of NPC converter and is very attractive in medium-voltage applications. In this paper, a new solution able to detect any type of power semiconductor switch fault inside the ANPC converter is proposed. This strategy allows to achieve fault tolerance of ANPC converter without alteration of the converter architecture, owing to the insertion of three couples of Rogowski coils in the six clamp branches.Keywords
This publication has 6 references indexed in Scilit:
- A new fault tolerant NPC converter system for high power induction motor drives2011
- Comparison of Medium Voltage IGBT-based 3L-ANPC-VSCs2008
- On the Operation of a Press Pack IGBT Module Under Short Circuit ConditionsIEEE Transactions on Advanced Packaging, 2006
- The active npc converter for medium-voltage applications2005
- The Active NPC Converter and Its Loss-Balancing ControlIEEE Transactions on Industrial Electronics, 2005
- Innovative press pack modules for high power IGBTs2002