A reliable and sensitive method has been developed and validated for the determination of cyazofamid in water using reverse phase HPLC (RP-HPLC). The analytical procedure involves fortification of water at two doses, liquid–liquid partition with chloroform, separation on Discovery C-18 column using mobile phase acetonitrile: water (60:40 v/v) and detection at 279 nm. Calibration curves for quantification were linear over the dynamic range of 0.01–10.0 µg mL−1 concentrations with the correlation coefficients (R2) greater than 0.99 and percent relative standard deviation [RSD (%) was 1.72. Degradation pattern indicated correspondence to monophasic first order kinetics in water with half-life values 3.92 and 4.25 days. The degradation rate was almost same at both treatments. The average recoveries of cyazofamid from water fortified at 0.01–5.0 µg mL−1 ranged from 90.4–96.6%. The limit of quantitation and limit of detection of analyte were 0.01 and 0.006 µg mL−1, respectively.

This publication has 13 references indexed in Scilit: