Prediction of Pedicle Screw Loosening For Lumbar Fusion Surgery With Preoperative Volume Of Interest-Based Hounsfield Units in Lumbar Vertebral Bodies On Computed Tomography
Authors:
- Masashi FujimotoMFMasashi Fujimoto
- Takahiro MiyazakiTMTakahiro Miyazaki
- Atsushi YamamotoAYAtsushi Yamamoto
- Shota ItoSIShota Ito
- Munenari IkezawaMIMunenari Ikezawa
- Satoru TaniokaSTSatoru Tanioka
- Hirofumi NishikawaHNHirofumi Nishikawa
- Yusuke KameiYKYusuke Kamei
- Masaki MizunoMMMasaki Mizuno
- Hidenori SuzukiHidenori Suzuki
- 3 November 2026
- journal article
- research article
- Published by Wolters Kluwer Health in Clinical Spine Surgery
Abstract
Study Design: Retrospective cohort study. Objective: To assess whether preoperative Hounsfield unit (HU) values measured using the volume of interest (VOI) method on computed tomography (CT) scans predict pedicle screw loosening after single-level lumbar fusion surgery. Summary of Background Data: Pedicle screw loosening is a major complication after spinal fusion surgery, particularly in patients with osteoporosis. While CT-derived HU values using region of interest (ROI) analysis have been associated with bone quality, the 3-dimensional VOI method enables volumetric assessment of the vertebral body. However, the clinical utility of VOI-based HU values for predicting screw loosening remains unclear. Methods: We retrospectively analyzed 82 patients who underwent single-level lumbar interbody fusion with bilateral pedicle screw fixation. HU values at L1–L5 were measured using a 3D VOI technique. Screw loosening was assessed using follow-up CT scans taken at least 12 months after surgery. Differences in HU values between the loosening and nonloosening groups were evaluated. Receiver operating characteristic (ROC) curve analysis was performed to determine cutoff HU values and predictive performance. Results: Pedicle screw loosening was observed in 26 out of 82 patients (31.7%). HU values were significantly lower in the loosening group across all vertebral levels ( P P <0.001). The average HU value across L1–L5 showed moderate predictive performance for screw loosening, with an area under the curve (AUC) of 0.723, a sensitivity of 88.5%, and a specificity of 50.0%. Conclusions: Preoperative VOI-based HU values were significantly associated with pedicle screw loosening after single-level lumbar fusion surgery and demonstrated moderate predictive performance. VOI-based HU assessment may serve as a potential adjunctive tool for preoperative risk stratification of pedicle screw loosening.Keywords
This publication has 22 references indexed in Scilit:
- Hounsfield units vs. vertebral bone quality score: which is a better predictor of screw loosening after single-level lumbar interbody fusion?European Spine Journal, 2025
- Assessing the utility of MRI-based vertebral bone quality (VBQ) for predicting lumbar pedicle screw looseningEuropean Spine Journal, 2023
- CT Hounsfield unit is a reliable parameter for screws loosening or cages subsidence in minimally invasive transforaminal lumbar interbody fusionScientific Reports, 2023
- Vertebral Bone Quality Score as a Predictor of Pedicle Screw Loosening Following Surgery for Degenerative Lumbar DiseaseSpine, 2023
- Beyond the pedicle screw–a patent reviewEuropean Spine Journal, 2022
- Incidence, Risk, and Outcome of Pedicle Screw Loosening in Degenerative Lumbar Scoliosis Patients Undergoing Long-Segment FusionGlobal Spine Journal, 2021
- The use of CT Hounsfield unit values to identify the undiagnosed spinal osteoporosis in patients with lumbar degenerative diseasesEuropean Spine Journal, 2018
- Radiology of OsteoporosisCanadian Association of Radiologists Journal, 2016
- Dynamic Contrast-Enhanced Magnetic Resonance Imaging Measurements in Renal Cell CarcinomaInvestigative Radiology, 2015
- Epidemiology, etiology, and diagnosis of osteoporosisAmerican Journal of Obstetrics and Gynecology, 2006