Utility of Very High Output Pace‐Capture Testing for Posterior Wall Isolation in Patients With Persistent Atrial Fibrillation
Authors:
- 5 April 2026
- journal article
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 37 (6) , 1182-1188
Abstract
Background: Pulmonary vein isolation (PVI) and posterior wall isolation (PWI) are frequently used in the treatment of persistent atrial fibrillation (AF). Minimal data support adjunct PWI, possibly due to lack of durability via epicardial reconnections. Objective: To determine the impact of very high output PW pace‐capture testing in patients with persistent AF on AF/AT recurrence. Methods: We performed a retrospective study of consecutive patients who underwent radiofrequency ablation for persistent AF and received PVI and PWI, as well as a cavotricuspid isthmus line (CTI). After the creation of three linear PW lesions (roof, carina‐to‐carina, and inferior PV levels), pace‐capture testing was performed on the PW. The first cohort confirmed PWI using 10 mA at 2 ms (10 × 2) to pace capture. Sequentially, the second cohort utilized 20 mA at 10 ms (20 × 10). If the PW was captured, additional lesions were performed. Patients were excluded if additional lesion sets beyond PVI, PWI, and CTI were performed. Results: A total of 232 patients were included. Of these, 129 (56%) patients were in the 20 × 10 group, and 103 (44%) patients were in the 10 × 2 group. The two groups did not differ in age, sex, proportion of comorbidities, presenting rhythm, left ventricular ejection fraction, or left atrial size. Despite the increase in procedure time and lesion number, in the time‐to‐event analysis, patients in the 20 × 10 group experienced recurrent AF/AT more frequently than those in the 10 × 2 group (log rank p = 0.01). Conclusion: Testing PWI in persistent AF with pace capture at 20 mA at 10 ms did not improve freedom from arrhythmia and may paradoxically be associated with harm. Our findings question whether PWI, regardless of durability, is effective in treating persistent AF.Keywords
This publication has 35 references indexed in Scilit:
- Impact of Left Atrial Ablation on the Atrial Contractile Function: Insights From Intracardiac Echocardiography and Electroanatomical Mapping in Persistent Atrial Fibrillation AblationJournal of Arrhythmia, 2025
- Pulsed-field ablation beyond pulmonary vein for persistent atrial fibrillation: efficacy and impact on left atrial functionJournal of Interventional Cardiac Electrophysiology, 2025
- Effect of electrical posterior wall isolation on left atrial mechanical functionJournal of Interventional Cardiac Electrophysiology, 2025
- Effect of Catheter Ablation Using Pulmonary Vein Isolation With vs Without Posterior Left Atrial Wall Isolation on Atrial Arrhythmia Recurrence in Patients With Persistent Atrial FibrillationJAMA, 2023
- Simultaneous pace-ablate during CARTO-guided pulmonary vein isolation with a contact-force sensing radiofrequency ablation catheterJournal of Interventional Cardiac Electrophysiology, 2018
- 2017 HRS/EHRA/ECAS/APHRS/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillation: Executive summaryHeart Rhythm, 2017
- Proven isolation of the pulmonary vein antrum with or without left atrial posterior wall isolation in patients with persistent atrial fibrillationHeart Rhythm, 2016
- Stiff left atrial syndrome after catheter ablation for atrial fibrillation: Clinical characterization, prevalence, and predictorsHeart Rhythm, 2011
- Outcomes of long-standing persistent atrial fibrillation ablation: A systematic reviewHeart Rhythm, 2010
- Loss of pace capture on the ablation line: A new marker for complete radiofrequency lesions to achieve pulmonary vein isolationHeart Rhythm, 2010