Improvement of deep learning prediction model in patient‐specific QA for VMAT with MLC leaf position map and patient's dose distribution
Authors:
Open Access
- 1 June 2023
- journal article
- research article
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 24 (10) , e14055
Abstract
Purpose: Deep learning‐based virtual patient‐specific quality assurance (QA) is a novel technique that enables patient QA without measurement. However, this method could be improved by further evaluating the optimal data to be used as input. Therefore, a deep learning‐based model that uses multileaf collimator (MLC) information per control point and dose distribution in patient's CT as inputs was developed.Methods: Overall, 96 volumetric‐modulated arc therapy plans generated for prostate cancer treatment were used. We developed a model (Model 1) that can predict measurement‐based gamma passing rate (GPR) for a treatment plan using data stored as a map reflecting the MLC leaf position at each control point (MLPM) and data of the dose distribution in patient's CT as inputs. The evaluation of the model was based on the mean absolute error (MAE) and Pearson's correlation coefficient (r) between the measured and predicted GPR. For comparison, we also analyzed models trained with the dose distribution in patient's CT alone (Model 2) and with dose distributions recalculated on a virtual phantom CT (Model 3).Results: At the 2%/2 mm criterion, MAE[%] and r for Model 1, Model 2, and Model 3 were 2.32% ± 0.43% and 0.54 ± 0.03, 2.70% ± 0.26%, and 0.32 ± 0.08, and 2.96% ± 0.23% and 0.24 ± 0.22, respectively; at the 3%/3 mm criterion, these values were 1.25% ± 0.05% and 0.36 ± 0.18, 1.57% ± 0.35% and 0.19 ± 0.20, and 1.39% ± 0.32% and 0.17 ± 0.22, respectively. This result showed that Model 1 exhibited the lowest MAE and highest r at both criteria of 2%/2 mm and 3%3 mm.Conclusions: These findings showed that a model that combines the MLPM and dose distribution in patient's CT exhibited a better GPR prediction performance compared with the other two studied models.Keywords
This publication has 29 references indexed in Scilit:
- Impact of plan parameters on the dosimetric accuracy of volumetric modulated arc therapyMedical Physics, 2013
- Patient QA systems for rotational radiation therapy: A comparative experimental study with intentional errorsMedical Physics, 2013
- Volumetric modulated arc therapy: a review of current literature and clinical use in practiceBritish Journal of Radiology, 2011
- Assessing software upgrades, plan properties and patient geometry using intensity modulated radiation therapy (IMRT) complexity metricsMedical Physics, 2011
- Per‐beam, planar IMRT QA passing rates do not predict clinically relevant patient dose errorsMedical Physics, 2011
- A new metric for assessing IMRT modulation complexity and plan deliverabilityMedical Physics, 2010
- IMRT commissioning: Multiple institution planning and dosimetry comparisons, a report from AAPM Task Group 119Medical Physics, 2009
- Task Group 142 report: Quality assurance of medical acceleratorsa)Medical Physics, 2009
- Novel dosimetric phantom for quality assurance of volumetric modulated arc therapyMedical Physics, 2009
- A literature review of electronic portal imaging for radiotherapy dosimetryRadiotherapy and Oncology, 2008