Test–retest reliability and validity in lower limb proprioception tests using image capture technique in healthy adults
Open Access
- 19 December 2024
- journal article
- research article
- Published by Springer Nature in Bulletin of Faculty of Physical Therapy
- Vol. 29 (1) , 1-13
Abstract
Background: Proprioceptive assessments in clinical practice remain confined to ordinal scales, with a lack of ratio scales. Quantitative proprioception assessments such as threshold to detect passive motion (TDPM) and joint position sense (JPS) help determine the severity of functional impairments and evaluate treatment efficacy. However, their clinical introduction remains challenging due to the extensive and costly equipment required for their measurement. Purpose: To investigate the test–retest reliability and validity in the simplified TDPM and JPS using 14 image capture techniques in targeting hip, knee, and ankle joints. Methods: This study included 16 volunteers. The measurements were conducted in individual rehabilitation rooms located within the wards of our hospital. Examiners measured a total of 12 TDPM and JPS, including hip, knee, and ankle joints, each performed three times. Moreover, the multi-joint TDPM, distinguished into lower limb flexion and extension patterns, was additionally performed. These measurements were repeated 1 week later. In statistical analysis, the test–retest reliability and construct validity were evaluated using intraclass correlation coefficients (ICC) and Spearman’s rank correlation coefficients. Results: The TDPM, multi-joint TDPM, and JPS (variable data; VE) demonstrated moderate reliability across all tested movement directions (TDPM: ICC 0.52–0.70, limits of agreement [LOA] < 10°; multi-joint TDPM: ICC 0.64–0.73, LOA < 10°; JPS: ICC 0.55–0.78, LOA < 10°). No significant correlation was observed between these tests. Conclusions: TDPM and JPS using image capture techniques can reliably measure proprioception and serve as independent tests to evaluate different aspects of proprioception. These findings contribute to future studies aimed at introducing quantitative proprioception tests into clinical practice and facilitating clinical decision-making for rehabilitation targeting proprioceptive impairment.Keywords
This publication has 35 references indexed in Scilit:
- Multi-joint Assessment of Proprioception Impairments PoststrokeArchives of Physical Medicine and Rehabilitation, 2023
- Effects of hip abduction and adduction accuracy on post-stroke gaitClinical Biomechanics, 2017
- Test–retest reliability of a new device for assessing ankle joint threshold to detect passive movement in healthy adultsJournal of Sports Sciences, 2015
- Reproducibility of a knee and hip proprioception test in healthy older adultsAging Clinical and Experimental Research, 2014
- Movement detection at the ankle following stroke is poorAustralian Journal of Physiotherapy, 2005
- Penny-wise and pound-foolish: the impact of measurement error on sample size requirements in clinical trialsBiological Psychiatry, 2000
- Ago-antagonist muscle spindle inputs contribute together to joint movement coding in manBrain Research, 1998
- Sample size and optimal designs for reliability studiesStatistics in Medicine, 1998
- Proprioception after an acute knee ligament injury: A longitudinal study on 16 consecutive patientsJournal of Orthopaedic Research, 1997
- Kinaesthetic role of muscle afferents in man, studied by tendon vibration and microneurographyExperimental Brain Research, 1982