Sound Localization and Sensitivity to Interaural Cues in Bilateral Users of the Med-El Combi 40/40+Cochlear Implant System
Authors:
- F SchoenFSF Schoen
- J MuellerJMJ Mueller
- J HelmsJHJ Helms
- P NoppPNP Nopp
- 1 May 2005
- journal article
- research article
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 26 (3) , 429-437
Abstract
The purpose of this study was to investigate sound localization in subjects bilaterally implanted with MED-EL COMBI 40/40+ cochlear implants. In addition, the sensitivity to interaural cues was assessed. In the localization test (11 subjects), CCITT noise (500 ms, original and HRTF-filtered, 70/75/80 dB sound pressure level) was presented from one of seven loudspeakers between −90° and 90° azimuth. The subject had to indicate which loudspeaker the noise was presented from. Sensitivity to interaural level differences (ILD) was assessed by performing localization tests (4 subjects) with the loudness of the two speech processors unbalanced to various degrees. To investigate the subjects' sensitivity to interaural time differences (ITD), lateralization was measured (7 subjects) as a function of the time difference between two Gaussian-like pulses, each directed to one of the subject's speech processor microphones by way of headphones. The judgments of all subjects significantly correlated with the positions of the loudspeakers. The scatter in the judged azimuth measured by the standard deviation of the responses was on average 27.5°. Unbalanced loudness of the speech processors produced a bias in azimuth toward the speech processor with the louder volume setting. The mean rate of shift was 1.4° per unit on the Wuerzburg loudness scale. Six of seven subjects showed a significant sensitivity to ITDs with the approximate time difference required for complete lateralization being 1,200 μs on an average. The one subject not showing a sensitivity to ITDs performed worst in the localization test. Bilateral cochlear implantation can restore spatial hearing in cochlear implant users. Both ILDs and ITDs are used by bilateral cochlear implant users in sound localization with ILDs appearing to be the dominant cue.Keywords
This publication has 9 references indexed in Scilit:
- Speech Reception Thresholds Obtained in a Symmetrical Four-Loudspeaker Arrangement from Bilateral Users of MED-EL Cochlear ImplantsOtology & Neurotology, 2002
- Speech Understanding in Quiet and Noise in Bilateral Users of the MED-EL COMBI 40/40+ Cochlear Implant SystemEar & Hearing, 2002
- Sound-Direction Identification, Interaural Time Delay Discrimination, and Speech Intelligibility Advantages in Noise for a Bilateral Cochlear Implant UserEar & Hearing, 2002
- Comparison of the TEMPO+ Ear-Level Speech Processor and the CIS PRO+ Body-Worn Processor in Adult MED-EL Cochlear Implant UsersORL, 2001
- On the source-identification methodThe Journal of the Acoustical Society of America, 1998
- Psychophysical studies with two binaural cochlear implant subjectsThe Journal of the Acoustical Society of America, 1997
- Evaluation of Performance with the COMBI 40 Cochlear Implant in Adults: A Multicentric Clinical StudyORL, 1997
- Psychophysical and speech perception studies: A case report on a binaural cochlear implant subjectThe Journal of the Acoustical Society of America, 1993
- Auditory Localisation by Hearing-Impaired Persons Using Binaural In-The-Ear Hearing AidsBritish Journal of Audiology, 1975