A novel, high-performance, low-volume, rapid luciferase immunoprecipitation system (LIPS) assay to detect autoantibodies to zinc transporter 8
Authors:
- Claire L WilliamsCWClaire L Williams
- Ilaria MarzinottoIMIlaria Marzinotto
- Kathleen M GillespieKGKathleen M Gillespie
- The BOX Study GroupTGThe BOX Study Group
- Isabel WilsonIWIsabel Wilson
- Rachel AitkenRARachel Aitken
- Clare MegsonCMClare Megson
- Chitrabhanu BallavCBChitrabhanu Ballav
- Atanu DuttaADAtanu Dutta
Open Access
- 27 December 2023
- journal article
- research article
- Published by Oxford University Press (OUP) in Clinical and Experimental Immunology
- Vol. 215 (3) , 215-224
Abstract
Zinc transporter 8 autoantibodies (ZnT8A) are thought to appear close to type 1 diabetes (T1D) onset and can identify high-risk multiple (≥2) autoantibody positive individuals. Radiobinding assays (RBA) are widely used for ZnT8A measurement but have limited sustainability. We sought to develop a novel, high-performance, non-radioactive luciferase immunoprecipitation system (LIPS) assay to replace RBA. A custom dual C-terminal ZnT8 (aa268-369; R325/W325) heterodimeric antigen, tagged with a NanoluciferaseTM (Nluc-ZnT8) reporter, and LIPS assay was developed. Assay performance was evaluated by testing sera from new onset T1D (n = 573), healthy schoolchildren (n = 521), and selected first-degree relatives (FDRs) from the Bart’s Oxford family study (n = 617; 164 progressed to diabetes). In new-onset T1D, ZnT8A levels by LIPS strongly correlated with RBA (Spearman’s r = 0.89; P < 0.0001), and positivity was highly concordant (94.3%). At a high specificity (95%), LIPS and RBA had comparable assay performance [LIPS pROC-AUC(95) 0.032 (95% CI: 0.029–0.036); RBA pROC-AUC(95) 0.031 (95% CI: 0.028–0.034); P = 0.376]. Overall, FDRs found positive by LIPS or RBA had a comparable 20-year diabetes risk (52.6% and 59.7%, respectively), but LIPS positivity further stratified T1D risk in FDRs positive for at least one other islet autoantibody detected by RBA (P = 0.0346). This novel, high-performance, cheaper, quicker, higher throughput, low blood volume Nluc-ZnT8 LIPS assay is a safe, non-radioactive alternative to RBA with enhanced sensitivity and ability to discriminate T1D progressors. This method offers an advanced approach to current strategies to screen the general population for T1D risk for immunotherapy trials and to reduce rates of diabetic ketoacidosis at diagnosis.Keywords
Funding Information
- Diabetes UK (14/0004472)
- KMG (14/0004869)
This publication has 44 references indexed in Scilit:
- Engineered Luciferase Reporter from a Deep Sea Shrimp Utilizing a Novel Imidazopyrazinone SubstrateACS Chemical Biology, 2012
- Zinc Transporter-8 Autoantibodies Improve Prediction of Type 1 Diabetes in Relatives Positive for the Standard Biochemical AutoantibodiesDiabetes Care, 2012
- Rising Incidence of Type 1 Diabetes Is Associated With Altered Immunophenotype at DiagnosisDiabetes, 2012
- Contribution of Antibodies Against IA-2β and Zinc Transporter 8 to Classification of Diabetes Diagnosed Under 40 Years of AgeDiabetes Care, 2011
- pROC: an open-source package for R and S+ to analyze and compare ROC curvesBMC Bioinformatics, 2011
- Harmonization of Glutamic Acid Decarboxylase and Islet Antigen-2 Autoantibody Assays for National Institute of Diabetes and Digestive and Kidney Diseases ConsortiaThe Journal of Clinical Endocrinology & Metabolism, 2010
- A Common Nonsynonymous Single Nucleotide Polymorphism in the SLC30A8 Gene Determines ZnT8 Autoantibody Specificity in Type 1 DiabetesDiabetes, 2008
- A New Luminescence Assay for Autoantibodies to Mammalian Cell–Prepared Insulinoma-Associated Protein 2Diabetes Care, 2008
- The cation efflux transporter ZnT8 (Slc30A8) is a major autoantigen in human type 1 diabetesProceedings of the National Academy of Sciences of the United States of America, 2007
- Can Islet Cell Antibodies Predict IDDM in the General Population?Diabetes Care, 1993