Non-rigid deformation to include subject-specific detail in musculoskeletal models of CP children with proximal femoral deformity and its effect on muscle and contact forces during gait
- 22 January 2019
- journal article
- research article
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 22 (4) , 376-385
Abstract
To account for proximal femoral deformities in children with cerebral palsy (CP), subject-specific musculoskeletal models are needed. Non-rigid deformation (NRD) deforms generic onto personalized bone geometry and thereby transforms the muscle points. The goal of this study was to determine to what extent the models and simulation outcomes in CP patients differ when including subject-specific detail using NRD or Magnetic Resonance Imaging (MRI)-based models. The NRD models slightly overestimated hip contact forces compared to MRI models and differences in muscle point positions and moment arm lengths (MALs) remained, although differences were smaller than for the generic model.Keywords
Funding Information
- KU Leuven’s Research Council under (IDO/07/012)
- Research Foundation Flanders (G.0395.09)
- Flanders Innovation and Entrepreneurship (3M140540)
This publication has 38 references indexed in Scilit:
- Hip contact force in presence of aberrant bone geometry during normal and pathological gaitJournal of Orthopaedic Research, 2014
- Compressive tibiofemoral force during crouch gaitGait & Posture, 2012
- Method for determining musculotendon parameters in subject-specific musculoskeletal models of children developed from MRI dataMultibody System Dynamics, 2012
- A Model of the Lower Limb for Analysis of Human MovementAnnals of Biomedical Engineering, 2009
- Kalman smoothing improves the estimation of joint kinematics and kinetics in marker-based human gait analysisJournal of Biomechanics, 2008
- Calculated moment-arm and muscle-tendon lengths during gait differ substantially using MR based versus rescaled generic lower-limb musculoskeletal modelsGait & Posture, 2008
- Personalized MR-based musculoskeletal models compared to rescaled generic models in the presence of increased femoral anteversion: Effect on hip moment arm lengthsGait & Posture, 2008
- Image‐based musculoskeletal modeling: Applications, advances, and future opportunitiesJournal of Magnetic Resonance Imaging, 2007
- Image Based Musculoskeletal Modeling Allows Personalized Biomechanical Analysis of Gait2006
- A planar model of the knee joint to characterize the knee extensor mechanismJournal of Biomechanics, 1989