Aqueous Chromatography Utilizing pH-/Temperature-Responsive Polymer Stationary Phases To Separate Ionic Bioactive Compounds
Authors:
- 27 March 2001
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 73 (9) , 2027-2033
Abstract
Cross-linked poly(N-isopropylacrylamide-co-acrylic acid) (poly(IPAAm-co-AAc))-grafted silica bead surfaces were prepared and applied as new column matrix materials that exploit temperature-responsive anionic chromatography to separate basic bioactive compounds, specifically catecholamine derivatives, in aqueous mobile phases. Since poly(IPAAm-co-AAc) has a well-known temperature-responsive phase transition and apparent pKa shift, polymer-grafted silica bead surfaces are expected to exhibit simultaneous hydrophilic/hydrophobic and charge density alterations under thermal stimuli. Elution behavior of catecholamine derivatives from a copolymer-modified bead packed column was monitored using aqueous mobile-phase HPLC under varying temperature and pH. Catecholamine derivatives had higher retention times on poly(IPAAm-co-AAc) columns at higher pH in comparison with those on noncharged PIPAAm reference columns, suggesting an electrostatic interaction as a separation mode. Temperature also affected the retention behavior of catecholamine derivatives. Optimal separation of four catecholamine derivatives was achieved at elevated temperature, 50 °C, and at pH 7.0. This is due to the increased hydrophobicity of the stationary phase as evidenced by the elution of a nonionic hydrophobic steroid. From these results, mutual influences of both electrostatic and hydrophobic interactions between basic catecholamine derivatives and pH-/temperature-responsive surfaces are noted. Consequently, elution of weakly charged bioactive compounds is readily regulated through the modulation of stationary-phase thermoresponsive hydrophilic/hydrophobic and charge density changes.Keywords
This publication has 18 references indexed in Scilit:
- Effects of Cross-Linked Structure on Temperature-Responsive Hydrophobic Interaction of Poly(N-isopropylacrylamide) Hydrogel-Modified Surfaces with SteroidsAnalytical Chemistry, 1999
- Rapid Deswelling Response of Poly(N-isopropylacrylamide) Hydrogels by the Formation of Water Release Channels Using Poly(ethylene oxide) Graft ChainsMacromolecules, 1998
- Temperature-Responsive Liquid Chromatography. 2. Effects of Hydrophobic Groups in N-Isopropylacrylamide Copolymer-Modified SilicaAnalytical Chemistry, 1997
- Temperature-responsive poly(N-isopropylacrylamide) as a modulator for alteration of hydrophilic/hydrophobic surface properties to control activation/inactivation of plateletsJournal of Controlled Release, 1995
- Mechanism of cell detachment from temperature-modulated, hydrophilic-hydrophobic polymer surfacesBiomaterials, 1995
- Temperature-modulated platelet and lymphocyte interactions with poly(N-isopropylacrylamide)-grafted surfacesBiomaterials, 1995
- In situ Surface-Selective Modification of Uniform Size Macroporous Polymer Particles with Temperature-Responsive Poly-N-isopropylacrylamideMacromolecules, 1994
- Heparin release from thermosensitive hydrogelsJournal of Controlled Release, 1992
- Mutual influence of pH and temperature on the swelling of ionizable and thermosensitive hydrogelsMacromolecules, 1992
- pH-dependent equilibrium swelling properties of hydrophobic polyelectrolyte copolymer gelsMacromolecules, 1988