Evaluation of surface contamination with staphylococci in a veterinary hospital using a quantitative microbiological method
- 26 October 2010
- journal article
- Published by Wiley in Journal of Small Animal Practice
- Vol. 51 (11) , 574-580
Abstract
Objectives: To evaluate microbial contamination of the environment in a veterinary hospital using standards recommended for human hospitals and to provide a baseline against which further investigations can be compared. Methods: Surfaces were sampled twice daily for five consecutive days using a contact‐based counting method to measure the levels of staphylococci in colony forming units (cfu) per cm2. Results: Current recommendations for human hospitals were applied in this study; all samples with 2 staphylococci were considered to have passed and those with ≥2.5cfu/cm2 to have failed. Of all the samples, 55.9% failed. The ICU did not have significantly higher failure rates than other areas of the hospital. The floor as a surface was associated with greater than a threefold increase in odds of elevated cfu concentrations relative to the door handle. Clinical Significance: This study provides information on the microbiological cleanliness of a veterinary teaching hospital using techniques and standards adopted by the food industry and recommended for human hospitals. This data can be used as a baseline for other hospitals, to evaluate the effectiveness in improvements in hygiene and cleaning measures and to design effective hospital cleaning protocols and assess ongoing hygiene standards.Keywords
This publication has 19 references indexed in Scilit:
- Prevalence and distribution of meticillin‐resistant Staphylococcus aureus within the environment and staff of a university veterinary clinicJournal of Small Animal Practice, 2009
- The effectiveness of existing and modified cleaning regimens in a Welsh hospitalJournal of Hospital Infection, 2007
- Prevalence of methicillin-resistant Staphylococcus aureus among staff and pets in a small animal referral hospital in the UKJournal of Antimicrobial Chemotherapy, 2005
- The environment as a significant cofactor for multiply resistant nosocomial infectionsSeminars in Respiratory Infections, 2002
- A comparison of surface sampling methods for detecting coliforms on food contact surfacesFood Microbiology, 2002
- Evidence that hospital hygiene is important in the control of methicillin-resistant Staphylococcus aureusJournal of Hospital Infection, 2001
- Surface disinfection: should we do it?Journal of Hospital Infection, 2001
- An evaluation of hospital cleaning regimes and standardsJournal of Hospital Infection, 2000
- Mopping up hospital infectionJournal of Hospital Infection, 1999
- Media used in the detection and enumeration of Staphylococcus aureusInternational Journal of Food Microbiology, 1995