Relationship between anterior capsule opening and direction of intraocular lens decentration
Open Access
- 1 September 2023
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 49 (9) , 917-920
Abstract
Purpose: To compare intraocular lens (IOL) decentration between patients in whom the continuous curvilinear capsulorhexis (CCC) completely covers the IOL optic and those in whom it incompletely covers the IOL optic and determine how an incompletely covered CCC affects the IOL position. Setting: Tertiary hospital in Japan. Design: Single-center retrospective study. Methods: 57 eyes of 57 patients (mean age 70.8 ± 6.2 years) that underwent phacoemulsification and IOL (SN60WF) implantation in the bag between April 2010 and April 2015 were included in this study. The patients were classified based on whether the CCC completely (CC group) or incompletely (NCC group) covered the IOL optic using an anterior eye segment analysis system (EAS-1000). The IOL decentration of the groups was analyzed using EAS-1000 at 1 week, 1 month, 3 months, and 6 months postoperatively and compared. The relationship between the NCC location and the IOL direction at 3 months postoperatively was analyzed. Results: The NCC group (25 eyes) had a significantly higher amount of IOL decentration than the CC group (32 eyes) at 1 week, 1 month, 3 months, and 6 months postoperatively (P < .05). There was a correlation between the direction of IOL decentration and the NCC location, and IOL decentration in the NCC group occurred in the opposite direction to the NCC area. Conclusions: An anterior capsule opening that completely covers the IOL optic is important to control IOL decentration.Keywords
This publication has 25 references indexed in Scilit:
- Effects of decentration and tilt on the optical performance of 6 aspheric intraocular lens designs in a model eyeJournal of Cataract & Refractive Surgery, 2019
- Effects of decentration and tilt at different orientations on the optical performance of a rotationally asymmetric multifocal intraocular lensJournal of Cataract & Refractive Surgery, 2019
- Effect of intraocular lens decentration on image quality tested in a custom model eyeJournal of Cataract & Refractive Surgery, 2018
- Inferior Decentration of Multifocal Intraocular Lenses in Myopic EyesAmerican Journal of Ophthalmology, 2018
- Effect of manual capsulorhexis size and position on intraocular lens tilt, centration, and axial positionJournal of Cataract & Refractive Surgery, 2017
- Intraoperative aberrometry versus standard preoperative biometry and a toric IOL calculator for bilateral toric IOL implantation with a femtosecond laser: One-month resultsJournal of Cataract & Refractive Surgery, 2016
- In vitro optical performance of nonrotational symmetric and refractive–diffractive aspheric multifocal intraocular lenses: Impact of tilt and decentrationJournal of Cataract & Refractive Surgery, 2012
- Impact of intraocular lens haptic design and orientation on decentration and tiltJournal of Cataract & Refractive Surgery, 2011
- Visual outcomes and optical performance of a monofocal intraocular lens and a new-generation multifocal intraocular lensJournal of Cataract & Refractive Surgery, 2011
- Optical performance of 3 intraocular lens designs in the presence of decentrationJournal of Cataract & Refractive Surgery, 2005