Computed tomographic study of the posterior condylar angle in arthritic knees: its use in the rotational positioning of the femoral implant of total knee prostheses
Authors:
- 1 August 2003
- journal article
- radiologic anatomy
- Published by Springer Nature in Surgical and Radiologic Anatomy
- Vol. 25 (3-4) , 330-334
Abstract
The epicondylar axis is a reliable reference to check the rotation of the femoral implant in total knee prostheses (TKPs). However, during the operation it seems easier to use the posterior condylar axis as a landmark. The angle between these two axes is called the posterior condylar angle (PCA). The aim of this study was to measure the PCA in arthritic knees to assess the reliability of the posterior condylar axis as a reference for the control of the rotation of the femoral implant and to look for correlation with other radiological measurements. This prospective study consisted of 103 arthritic knees (81 varus, 22 valgus) before a TKP had been done in 103 patients (75 women, 28 men). The assessment of the PCA was made by computed tomographic scanning (CT). The HKA, HKS and HKT angles were measured on the pangonogram. The posterior condylar axis was internally rotated with respect to the epicondylar axis. The average value for all the patients was 2.65° degrees with a range from 0° to 7°. The PCA was significantly increased in the valgus knees. There was no correlation between the angles on the pangonogram and the posterior condylar axis. While the preoperative assessment of the PCA by CT scanning is reliable, the results obtained indicate the marked variability in its value. If one wishes to use the posterior condylar axis as a guide for rotation, it is therefore necessary to assess the PCA for each patient using adjustable jigs according to the value obtained. No measurement on standard radiographs allowed an extrapolation of the value of the PCA, and CT scanning seems to be the preferable radiological examination.Keywords
This publication has 29 references indexed in Scilit:
- Anatomic variations should be considered in total knee arthroplastyJournal of Orthopaedic Science, 2000
- Anatomy of the epicondyles of the distal femurThe Journal of Arthroplasty, 2000
- Assessment of relative rotational alignment in total knee arthroplasty: usefulness of the modified Eckhoff methodJournal of Orthopaedic Science, 2000
- Reliability of the anteroposterior axis and the posterior condylar axis for determining rotational alignment of the femoral component in total knee arthroplastyJournal of Orthopaedic Science, 1998
- Femoral Rotational Alignment Using the Tibial Shaft Axis in Total Knee ArthroplastyClinical Orthopaedics and Related Research, 1996
- Rotational Landmarks and Sizing of the Distal Femur in Total Knee ArthroplastyClinical Orthopaedics and Related Research, 1996
- Location of the femoral sulcus in the osteoarthritic kneeThe Journal of Arthroplasty, 1996
- Flexion space configuration in total knee arthroplastyThe Journal of Arthroplasty, 1995
- Implications of reference axes used for rotational alignment of the femoral component in primary and revision knee arthroplastyThe Journal of Arthroplasty, 1992
- Recurrent infection of a total hip arthroplasty associated with radiation-induced ulcerative colitisThe Journal of Arthroplasty, 1989