Biomechanical comparison of augmented versus non-augmented sacroiliac screws in a novel hemi-pelvis test model
Open Access
- 26 August 2016
- journal article
- research article
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 35 (7) , 1485-1493
Abstract
Operative treatment of sacral insufficiency fractures is frequently being complicated by osteopenic bone properties. Cement augmentation of implanted sacroiliac screws may lead to superior construct stability and prevent mechanical complications. A novel hemi‐pelvis test model with dissected symphysis was developed. Five fresh‐frozen cadaveric pelvises were vertically osteotomized at the sacrum on both sides and fixed with sacroiliac screws in both corridors of the first sacral vertebral body. One side was randomly augmented with bone cement. Cyclic testing consisting of torsional loading (±2.5 Nm) combined with progressively increasing axial loading (+50 N compression, −10 N traction, ±0,01 N/cycle) was performed until failure; simulated physiological loads derived from inverse dynamic calculations. The fixation was analyzed fluoroscopically quantifying screw migrations and assessing failure mechanisms. Failure modes were cut‐out, pull‐out, screw‐out, and washer penetration. Motion at fracture site was analyzed via optical motion tracking. Unscrewing was provoked four times with non‐augmented and twice with augmented screws. When focusing on the sacral region only, cement augmentation significantly improved screw fixation in terms of increased number of cycles to failure (p = 0.043). However, when considering overall construct stability, there was no significant difference between augmented and non‐augmented state due to washer penetration at the iliac bone. The generated hemi‐pelvis model was found to be valid due to the reproduction of the clinically observed failure mode (unscrewing). Unscrewing was not fully prevented by cement augmentation. Augmentation effects stability at the screw tip, but particularly in porotic bone, failure may shift to the next weak point. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:1485–1493, 2017.Keywords
Funding Information
- AOTRAUMA Network (AR2008_01)
This publication has 25 references indexed in Scilit:
- Surgical management of osteoporotic pelvic fractures: a new challengeEuropean Journal of Trauma and Emergency Surgery, 2012
- Biomechanical testing of a concept of posterior pelvic reconstruction in rotationally and vertically unstable fracturesThe Journal of Bone and Joint Surgery. British volume, 2011
- Fractures of the hip and osteoporosisThe Journal of Bone and Joint Surgery. British volume, 2009
- Anatomical and Biomechanical Analyses of the Unique and Consistent Locations of Sacral Insufficiency FracturesSpine, 2009
- Computer Assisted Percutaneous Placement of Augmented Iliosacral ScrewsSpine, 2008
- Sacral insufficiency fractureBritish Journal of Radiology, 2004
- Sacroiliac Screw Fixation for Tile B Fractures2003
- Fixation of Transforaminal Sacrum FracturesJournal of Orthopaedic Trauma, 1993
- Sacral FracturesClinical Orthopaedics and Related Research, 1988
- Posterior Stabilization of Pelvic Fractures by Use of Threaded Compression RodsClinical Orthopaedics and Related Research, 1985