Abstract
Wear analysis of total hip replacements (THRs) is considered one of the most relevant research areas helping to improve the longevity and overall design of THRs. The coordinate machine method (CMM) and Fourier profilometry are the most common methods for measuring THR wear. This article presents optical scanner digitalization as a new method for measuring the wear of polyethylene (PE) acetabular cups. The aim of this article is to explore the potential of this method for the PE wear measurements. Optical scans for the purposes of this study were produced using an ATOS Triple Scan 3D optical scanner. The optical scanner is efficient and it can measure a large number of points for polygonization and for further development of the preworn models. In this study, the scanner first generated point clouds on a sample of 13 retrieved ultra-high-molecular-weight polyethylene (UHMWPE) acetabular cups. Next, volumetric models of the cups were created by polygonizing the point clouds. Reverse engineering was used to develop models of the original acetabular cups using the geometry of the unworn parts of the retrieved cups. A comparison of the two models then showed the total volume of the PE debris. The optical scanning method was validated against the gravimetric method using three new acetabular cups that were worn out on a hip pendulum simulator. Validation shows that the optical scanning method is a valid method for wear analysis of the retrieved UHMWPE acetabular cups.Keywords
This publication has 28 references indexed in Scilit:
- Particle disease: Biologic mechanisms of periprosthetic osteolysis in total hip arthroplastyInnate Immunity, 2012
- Acetabular polyethylene wear volume after hip replacement: Reliability of volume calculations from plain radiographsWear, 2012
- Volumetric wear assessment of failed metal-on-metal hip resurfacing prosthesesWear, 2011
- The lexicon of polyethylene wear in artificial jointsBiomaterials, 2007
- Development of a technique for accurately determining clinical wear in explanted total hip replacementsWear, 2007
- Highly Crosslinked Polyethylenes in Hip Replacements: Improved Wear Performance or Paradox?Tribology Transactions, 2007
- Projections of Primary and Revision Hip and Knee Arthroplasty in the United States from 2005 to 2030Journal of Bone and Joint Surgery, 2007
- Measurements of sequential impressions of acetabula cups from a total hip joint replacement using a non-contact measurement systemInternational Journal of Machine Tools and Manufacture, 2001
- The effect of joint loading on acetabular wear measurement in total hip arthroplastyThe Journal of Arthroplasty, 2000
- Surface Geometry of Retrieved McKee-Farrar Total Hip ReplacementsClinical Orthopaedics and Related Research, 1996