Bioabsorbable interference screw versus bioabsorbable cross pins: influence of femoral graft fixation on the clinical outcome after ACL reconstruction
Open Access
- 31 January 2012
- journal article
- clinical trial
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 20 (11) , 2251-2256
Abstract
Purpose: The aim of this study was to evaluate the clinical outcome and differences in anterior–posterior laxity of ACL reconstruction using a bioabsorbable interference screw for femoral graft fixation when compared to femoral bioabsorbable cross pin fixation.Methods: Clinical outcome was evaluated among 59 patients 1 year after arthroscopic ACL reconstruction with hamstrings graft in a prospective, non‐randomised study. In 31 cases, femoral fixation of the graft was performed using a bioabsorbable interference screw. In 28 cases, two bioabsorbable cross pins were used for femoral fixation. Patients were evaluated using Tegner, Lysholm and Marshall scores, the visual analogue scale for pain and KT‐1000 arthrometer measurement.Results: No significant difference (P ≥ 0.05) was observed at follow‐up for the knee scores. The average Tegner score was 5.83 points (±2.00) for the interference screw fixation and 5.83 points (±1.24) for the cross pin fixation; the average Lysholm score was 93.58 (±5.79) to 92.72 (±6.34) points; and the average Marshall score 46.72 (±2.4) to 47.30 (±2.35) points. No significant difference was found for the visual analogue scale for pain. KT‐1000 arthrometer measurement revealed a significant (P < 0.05) difference in the mean side‐to‐side anterior translation at all applied forces. At 67 N, the mean difference was 1.53 mm (±1.24) in the interference screw group and 0.47 mm (±1.18) in the cross pin group (P < 0.05). At 89 N, the mean differences were 1.85 mm (±1.29) versus 0.59 mm (±1.59), respectively, (P < 0.05), and maximum manual displacements were 2.02 mm (±1.26) versus 1.22 mm (1.18; P < 0.05).Conclusions: In ACL reconstruction with hamstrings graft, similar clinical results are obtained for the use of bioabsorbable cross pins when compared to bioabsorbable interference screws for femoral fixation. Cross pin fixation was superior with regard to the anteroposterior laxity as measured with KT‐1000.Keywords
This publication has 32 references indexed in Scilit:
- A prospective randomized study of ACL‐reconstructions using bone‐patellar tendon‐bone grafts fixed with bioabsorbable or metal interference screwsKnee Surgery, Sports Traumatology, Arthroscopy, 2011
- Magnetic resonance imaging analysis of the bioabsorbable Milagro™ interference screw for graft fixation in anterior cruciate ligament reconstructionStrategies in Trauma and Limb Reconstruction, 2009
- A Prospective Comparison of 3 Hamstring ACL Fixation Devices—Rigidfix, BioScrew, and Intrafix—Randomized into 4 Groups with 2 Years of Follow-UpThe American Journal of Sports Medicine, 2009
- Current Concepts Review: Revision Anterior Cruciate Ligament ReconstructionThe American Journal of Sports Medicine, 2006
- Graft Laceration and Pullout Strength of Soft‐Tissue Anterior Cruciate Ligament Reconstruction: In Vitro Study Comparing Titanium, Poly‐D,L‐Lactide, and Poly‐D,L‐Lactide–Tricalcium Phosphate ScrewsArthroscopy, 2006
- Magnetic Resonance Imaging Analysis of Bioabsorbable Interference Screws Used for Fixation of Bone-Patellar Tendon-Bone Autografts in Endoscopic Reconstruction of the Anterior Cruciate LigamentThe American Journal of Sports Medicine, 2006
- Relationships between Objective Assessment of Ligament Stability and Subjective Assessment of Symptoms and Function after Anterior Cruciate Ligament ReconstructionThe American Journal of Sports Medicine, 2004
- Initial Fixation Strength of Two Bioabsorbable Pins for the Fixation of Hamstring Grafts Compared to Interference Screw FixationThe American Journal of Sports Medicine, 2004
- Revision Anterior Cruciate Ligament Surgery: Experience From PittsburghClinical Orthopaedics and Related Research, 1996
- Activation of the complement system and adverse effects of biodegradable pins of poly-lactic acid (Biofix®) in osteochondritis dissecansActa Orthopaedica, 1994